{"id":1332,"date":"2020-10-16T00:53:28","date_gmt":"2020-10-16T00:53:28","guid":{"rendered":"https:\/\/pistonpumps.top\/ztd-series-horizontal-fgd-desulphurization-slurry-circulation-pump\/"},"modified":"2020-10-16T00:53:28","modified_gmt":"2020-10-16T00:53:28","slug":"ztd-series-horizontal-fgd-desulphurization-slurry-circulation-pump","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/en_au\/ztd-series-horizontal-fgd-desulphurization-slurry-circulation-pump\/","title":{"rendered":"Ztd Series Horizontal Fgd Desulphurization Slurry Circulation Pump"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Ztd Series Horizontal Fgd Desulphurization Slurry Circulation Pump\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Ztd Series Horizontal Fgd Desulphurization Slurry Circulation Pump\" \/><\/p>\n<p><p>                                    <u><em><strong>Biref introduction:<\/strong><\/em><\/u><br \/>ZTD flue fuel desulfurization pump was elaborately created to satisfy the demands of damp method FGD of limestone(lime) and gypsum for coal fired electricity plants.The hydraulic types of ZTD desulfurization pump is optimized made by CFD,and its passage is made below the theory of abrasion of slurry pump.The wetted areas materials for ZTD desulfurization pump is an anti-abrasive and anti-corrosive content which was designed by HangZhou Pump alone. The biggest diameter of ZTD series is 900 mm at present, and it is commonly utilised in the flue fuel desulfurization and denitration approach of electrical power plant and other atmosphere security tasks.\u00a0<\/p>\n<p><u><em><strong>Parameters:<\/strong><\/em><\/u><\/p>\n<ol>\n<li>Flow\u00a0rate:Q=seven hundred~14000\u00a0(m\u00b3\/h)<\/li>\n<li>Total\u00a0head:H=15~63\u00a0(m)<\/li>\n<li>Pace:n=420~980rpm<\/li>\n<li>S.g.:\u03b3\u00a0\u22641.5\u00a0<\/li>\n<li>Temperature:T=~120\u00baC\u00a0<\/li>\n<li>Pump\u00a0diameter:three hundred~900mm<\/li>\n<\/ol>\n<p><u><em><strong>Features:<\/strong><\/em><\/u><\/p>\n<ol>\n<li>Elaborately\u00a0designed\u00a0based\u00a0on\u00a0the\u00a0characters\u00a0of\u00a0flue\u00a0gas\u00a0desulfurization\u00a0of\u00a0thermal\u00a0power\u00a0plant\u00a0to\u00a0meet\u00a0the\u00a0requirements\u00a0of\u00a0a\u00a0facility\u00a0below\u00a01000\u00a0MW.<\/li>\n<li>CZPT\u00a0models\u00a0are\u00a0CFD\u00a0optimized\u00a0to\u00a0have\u00a0excellent\u00a0performance\u00a0of\u00a0anti-cavitation.<\/li>\n<li>Specially\u00a0designed\u00a0mechanical\u00a0seal\u00a0for\u00a0flue\u00a0gas\u00a0desulfurization\u00a0process.\u00a0<\/li>\n<li>The\u00a0impeller\u00a0position\u00a0can\u00a0be\u00a0adjusted\u00a0by\u00a0the\u00a0bearing\u00a0housing,this\u00a0brings\u00a0a\u00a0shortcut\u00a0to\u00a0recover\u00a0the\u00a0pump\u00a0performance\u00a0under\u00a0a\u00a0slightly\u00a0abrasion.<\/li>\n<li>Axial\u00a0adjusting\u00a0structure\u00a0to\u00a0maintain\u00a0the\u00a0distance\u00a0between\u00a0impeller\u00a0and\u00a0front\u00a0cover\u00a0plate\u00a0to\u00a0keep\u00a0a\u00a0high\u00a0efficient\u00a0operation.<\/li>\n<li>The\u00a0specially\u00a0designed\u00a0anti-corrosive\u00a0and\u00a0anti-abrasive\u00a0duplex\u00a0stainless\u00a0white\u00a0iron\u00a0for\u00a0FGD\u00a0process,which\u00a0has\u00a0the\u00a0advantages\u00a0of\u00a0both\u00a0duplex\u00a0stainless\u00a0steel\u00a0and\u00a0white\u00a0anti-abrasive\u00a0iron\u00a0alloy.<\/li>\n<\/ol>\n<p><u><em><strong>Composition:<\/strong><\/em><\/u><\/p>\n<ol>\n<li>All\u00a0metal\u00a0materials\u00a0for\u00a0pump\u00a0set,without\u00a0any\u00a0lining\u00a0rubber\u00a0or\u00a0other\u00a0high\u00a0polymer\u00a0material.<\/li>\n<li>Pump\u00a0casing\u00a0adopts\u00a0duplex\u00a0stainless\u00a0steel\u00a0of\u00a02605N\u00a0and\u00a02205,which\u00a0have\u00a0excellent\u00a0resistant\u00a0performance\u00a0of\u00a0chloride\u00a0ions\u00a0and\u00a0sulfate\u00a0ions,and\u00a0therefore\u00a0is\u00a0the\u00a0first\u00a0choice\u00a0of\u00a0desulfurization\u00a0pumps.<\/li>\n<li>Front\u00a0and\u00a0back\u00a0open\u00a0structure,the\u00a0rotary\u00a0part\u00a0can\u00a0be\u00a0removed\u00a0from\u00a0the\u00a0casing\u00a0without\u00a0dismantling\u00a0the\u00a0pipelines.<\/li>\n<li>Cartridge\u00a0mechanical\u00a0seal\u00a0with\u00a0internal\u00a0or\u00a0external\u00a0flushing\u00a0plans.<\/li>\n<li>The\u00a0bearing\u00a0part\u00a0is\u00a0back\u00a0pull\u00a0structure,which\u00a0is\u00a0assembled\u00a0in\u00a0the\u00a0bearing\u00a0housing.<\/li>\n<li>Transmission:\u00a0directly\u00a0coupled\u00a0and\u00a0gear\u00a0box\u00a0drive.<\/li>\n<\/ol>\n<p>Structure\u00a0drawing\u00a0is\u00a0as\u00a0below<\/p>\n<p>\n<p>\n<p>\n<p>1.bearing\u00a0cover\u00a02.filler\u00a0cover\u00a03.shaft\u00a04.filler\u00a05.vice-impeller\u00a06.pump\u00a0body\u00a07.impeller\u00a0nut\u00a08.front\u00a0pump\u00a0cover\u00a09.impeller\u00a010.back\u00a0pump\u00a0body\u00a011.shaft\u00a0sleeve\u00a012.bearing\u00a0box\u00a013.bracket\u00a014.bearing\u00a0box\u00a015.bearing\u00a016.bearing\u00a0gland\u00a017.shaft\u00a0<\/p>\n<p><u><em><strong>Configuration:<\/p>\n<p>Software:<\/strong><\/em><\/u><\/p>\n<ol>\n<li>Mainly\u00a0used\u00a0as\u00a0circulation\u00a0pump\u00a0of\u00a0gypsum\u00a0slurry\u00a0of\u00a0absorbing\u00a0tower\u00a0of\u00a0FGD\u00a0process.<\/li>\n<li>Slurry\u00a0pump\u00a0of\u00a0ammonium\u00a0phosphate<\/li>\n<li>Other\u00a0applications\u00a0of\u00a0big\u00a0flow\u00a0rate\u00a0and\u00a0low\u00a0head.<\/li>\n<\/ol>\n<p>\n<p>\u00a0<\/p>\n<p>\n<p>\n<p>\n<p><p><img decoding=\"async\" style=\"height:auto\" title=\"Ztd Series Horizontal Fgd Desulphurization Slurry Circulation Pump\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Ztd Series Horizontal Fgd Desulphurization Slurry Circulation Pump\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Biref introduction:ZTD flue fuel desulfurization pump was elaborately created to satisfy the demands of damp method FGD of limestone(lime) and gypsum for coal fired electricity plants.The hydraulic types of ZTD desulfurization pump is optimized made by CFD,and its passage is made below the theory of abrasion of slurry pump.The wetted areas materials for ZTD desulfurization [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1332","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/1332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/comments?post=1332"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/1332\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/media?parent=1332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/categories?post=1332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/tags?post=1332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}