{"id":1823,"date":"2022-03-25T22:48:50","date_gmt":"2022-03-25T22:48:50","guid":{"rendered":"https:\/\/pistonpumps.top\/suncenter-wholesaler-pneumatic-hydraulic-piston-pump-with-ce-certificate-top-quality-low-price\/"},"modified":"2022-03-25T22:48:50","modified_gmt":"2022-03-25T22:48:50","slug":"suncenter-wholesaler-pneumatic-hydraulic-piston-pump-with-ce-certificate-top-quality-low-price","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/en_au\/suncenter-wholesaler-pneumatic-hydraulic-piston-pump-with-ce-certificate-top-quality-low-price\/","title":{"rendered":"Suncenter  wholesaler Pneumatic Hydraulic Piston Pump with ce certificate top quality low price"},"content":{"rendered":"<p>\n<h2>Product Description<\/h2>\n<p>\n<p>                        <strong>Suncenter pneumatic hydraulic piston pump<\/strong><br \/>We offer the most complete range of Air driven liquid pump models in the industry measured for:<\/p>\n<ol>\n<li>Capability of ultimate pressure, flow or output horsepower. <\/li>\n<li>Compatibility with a broad variety of liquids, such as oil, water and chemical applications.<\/li>\n<\/ol>\n<p>SUNCENTER pumps are air driven at a drive air pressure of 1bar to 8bar (14.5 psi to116 psi) by the normal CZPT . Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4\/2 way valve.<\/p>\n<p>Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. CZPT er pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the CZPT  shop air pressure, the nominal liquid pressure can be calculated.<\/p>\n<p>SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator. <br \/>The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. CZPT  liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don&#8217;t reduce the indicated port sizes and consult CZPT  for exact flow conditions not shown in charts.<\/p>\n<p><strong>Applications include:<\/strong><br \/>\u00a0<\/p>\n<ol>\n<li>\u00a0Pressure testing<\/li>\n<li>\u00a0Burst(Hydrostatic) testing<\/li>\n<li>\u00a0Work holding\/power clamping<\/li>\n<li>\u00a0Jacking\/lifting<\/li>\n<li>\u00a0Valve actuator control<\/li>\n<li>\u00a0Hydraulic cylinder actuation<\/li>\n<li>\u00a0Press safety overload devices<\/li>\n<li>\u00a0Roller tensioning<\/li>\n<li>\u00a0Metering<\/li>\n<li>\u00a0Precision lubrication and spraying<\/li>\n<li>\u00a0Liquefied gas transfer<\/li>\n<\/ol>\n<p><strong>Key features include: <\/strong><br \/>\u00a0<\/p>\n<ol>\n<li>Compressed Air driven &#8211; no electricity required (connect to normal CZPT )<\/li>\n<li>In order to extend the lifetime of the pump, the driving air pressure should <\/li>\n<\/ol>\n<p>not be higher than 8 bar<\/p>\n<ol>\n<li>No airline lubricator required <\/li>\n<li>Pressures to 640Mpa (6400 bar)\u00a0 <\/li>\n<li>Wide range of models with different ratios<\/li>\n<li>Built-in-cooling on most models <\/li>\n<li>Easy to install, operate and maintain<\/li>\n<li>Best price \/ performance ratio <\/li>\n<li>No heat, flame or spark risk and explosion proof <\/li>\n<li>Automatic pressure holding, whatever the cause of the pressure drop, the CZPT center\u00a0\u00a0 pump will automatically start, keep the loop pressure constant<\/li>\n<\/ol>\n<p><strong>DGM Series Liquid Pumps(Single acting, single air drive head)<\/strong><\/p>\n<ol>\n<li>They have aluminum bodies, with oxidation treatment and wetted materials of carbon steel or stainless steel, which depending on different service liquid. Material of stainless steel, making them an excellent choice of water application.<\/li>\n<li>Portable design.<\/li>\n<li>High quality seals, CZPT  service life CZPT <\/li>\n<li>Easy to install, operate and maintenance.<\/li>\n<li>Explosion proof and no electrical CZPT  required.<\/li>\n<\/ol>\n<p>\u00a0<\/p>\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Pressure \u00a0Boost Ratio<\/td>\n<td>Driven air pressure P<sub>L<\/sub> <\/td>\n<td>Formula to calculate outlet pressure<\/td>\n<td>MAX Outlet<br \/>Pressure(bar)*<\/td>\n<td>Liquid inlet Connection<\/td>\n<td>Liquid outlet Connection<\/td>\n<td>MaxFlow rate(L\/min)**<\/td>\n<\/tr>\n<tr>\n<td>DGM1<\/td>\n<td>1:1<\/td>\n<td>2-8 bar<\/td>\n<td>1XP<sub>L<\/sub><\/td>\n<td>8<\/td>\n<td>NPT1<\/td>\n<td>NPT1\/2<\/td>\n<td>20.50<\/td>\n<\/tr>\n<tr>\n<td>DGM4<\/td>\n<td>4:1<\/td>\n<td>2-8 bar<\/td>\n<td>4XP<sub>L<\/sub><\/td>\n<td>32<\/td>\n<td>NPT1<\/td>\n<td>NPT1\/2<\/td>\n<td>15.36<\/td>\n<\/tr>\n<tr>\n<td>DGM10<\/td>\n<td>10:1<\/td>\n<td>2-8 bar<\/td>\n<td>10XP<sub>L<\/sub><\/td>\n<td>80<\/td>\n<td>NPT3\/4<\/td>\n<td>NPT1\/2<\/td>\n<td>7.15<\/td>\n<\/tr>\n<tr>\n<td>DGM16<\/td>\n<td>16:1<\/td>\n<td>2-8 bar<\/td>\n<td>16XP<sub>L<\/sub><\/td>\n<td>128<\/td>\n<td>NPT \/2<\/td>\n<td>NPT\u00a01\/2<\/td>\n<td>4.59<\/td>\n<\/tr>\n<tr>\n<td>DGM30<\/td>\n<td>30:1<\/td>\n<td>2-8 bar<\/td>\n<td>30XP<sub>L<\/sub><\/td>\n<td>240<\/td>\n<td>NPT 1\/2<\/td>\n<td>NPT\u00a03\/8<\/td>\n<td>2.53<\/td>\n<\/tr>\n<tr>\n<td>DGM44<\/td>\n<td>44:1<\/td>\n<td>2-8 bar<\/td>\n<td>44XP<sub>L<\/sub><\/td>\n<td>352<\/td>\n<td>NPT 3\/8<\/td>\n<td>NPT\u00a03\/8<\/td>\n<td>1.41<\/td>\n<\/tr>\n<tr>\n<td>DGM64<\/td>\n<td>64:1<\/td>\n<td>2-8 bar<\/td>\n<td>64XP<sub>L<\/sub><\/td>\n<td>512<\/td>\n<td>NPT 3\/8<\/td>\n<td>NPT\u00a03\/8<\/td>\n<td>0.95<\/td>\n<\/tr>\n<tr>\n<td>DGM100<\/td>\n<td>100:1<\/td>\n<td>2-8 bar<\/td>\n<td>100XP<sub>L<\/sub><\/td>\n<td>800<\/td>\n<td>NPT 3\/8<\/td>\n<td>NPT\u00a03\/8<\/td>\n<td>0.64<\/td>\n<\/tr>\n<tr>\n<td>DGM170<\/td>\n<td>170:1<\/td>\n<td>2-8 bar<\/td>\n<td>170XP<sub>L<\/sub><\/td>\n<td>1360<\/td>\n<td>NPT 3\/8<\/td>\n<td>M14*1.5<\/td>\n<td>0.37<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The outlet liquid pressure=Driven air pressure*boost ratio<br \/>In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar<br \/><strong>DGG Series Liquid Pumps(Single acting, single air drive head)<\/strong><\/p>\n<ol>\n<li>DGG pumps have aluminum bodies and wetted materials of stainless steel or carbon steel ,which<\/li>\n<\/ol>\n<p>\u00a0\u00a0depends on different service liquid. CZPT  of stainless steel, make them an excellent choice<br \/>of water application. CZPT  quality seals, CZPT  service life CZPT .<\/p>\n<p><strong><\/p>\n<p>Technical specification<\/strong><br \/>\u00a0<\/p>\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Pressure\u00a0 Boost Ratio<\/td>\n<td>Driven air pressure P<sub>L<\/sub> <\/td>\n<td>Formula to calculate outlet pressure<\/td>\n<td>MAX Outlet<br \/>Pressure(bar)*<\/td>\n<td>Liquid inlet Connection<\/td>\n<td>Liquid outlet Connection<\/td>\n<td>MAX Flow (L\/min) <\/td>\n<\/tr>\n<tr>\n<td>DGG6<\/td>\n<td>6:1<\/td>\n<td>2-8 bar<\/td>\n<td>6XP<sub>L<\/sub><\/td>\n<td>48<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>29.91<\/td>\n<\/tr>\n<tr>\n<td>DGG10<\/td>\n<td>10:1<\/td>\n<td>2-8 bar<\/td>\n<td>10XP<sub>L<\/sub><\/td>\n<td>80<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>18.84<\/td>\n<\/tr>\n<tr>\n<td>DGG16<\/td>\n<td>16:1<\/td>\n<td>2-8 bar<\/td>\n<td>16XP<sub>L<\/sub><\/td>\n<td>128<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>12.42<\/td>\n<\/tr>\n<tr>\n<td>DGG28<\/td>\n<td>28:1<\/td>\n<td>2-8 bar<\/td>\n<td>28XP<sub>L<\/sub><\/td>\n<td>224<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>7.11<\/td>\n<\/tr>\n<tr>\n<td>DGG40<\/td>\n<td>40:1<\/td>\n<td>2-8 bar<\/td>\n<td>40XP<sub>L<\/sub><\/td>\n<td>320<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>4.89<\/td>\n<\/tr>\n<tr>\n<td>DGG64<\/td>\n<td>64:1<\/td>\n<td>2-8 bar<\/td>\n<td>64XP<sub>L<\/sub><\/td>\n<td>512<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT3\/8<\/td>\n<td>3.08<\/td>\n<\/tr>\n<tr>\n<td>DGG80<\/td>\n<td>80:1<\/td>\n<td>2-8 bar<\/td>\n<td>80XP<sub>L<\/sub><\/td>\n<td>640<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT3\/8<\/td>\n<td>2.44<\/td>\n<\/tr>\n<tr>\n<td>DGG100<\/td>\n<td>100:1<\/td>\n<td>2-8 bar<\/td>\n<td>100XP<sub>L<\/sub><\/td>\n<td>800<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT3\/8<\/td>\n<td>1.92<\/td>\n<\/tr>\n<tr>\n<td>DGG130<\/td>\n<td>130:1<\/td>\n<td>2-8 bar<\/td>\n<td>130XP<sub>L<\/sub><\/td>\n<td>1040<\/td>\n<td>NPT1\/2<\/td>\n<td>M14X1.5<\/td>\n<td>1.47<\/td>\n<\/tr>\n<tr>\n<td>DGG175<\/td>\n<td>175:1<\/td>\n<td>2-8 bar<\/td>\n<td>175XP<sub>L<\/sub><\/td>\n<td>1400<\/td>\n<td>NPT3\/8<\/td>\n<td>M14X1.5<\/td>\n<td>1.14<\/td>\n<\/tr>\n<tr>\n<td>DGG255<\/td>\n<td>255:1<\/td>\n<td>2-8 bar<\/td>\n<td>255XP<sub>L<\/sub><\/td>\n<td>2040<\/td>\n<td>NPT1\/4<\/td>\n<td>M14X1.5<\/td>\n<td>0.75<\/td>\n<\/tr>\n<tr>\n<td>DGG400<\/td>\n<td>400:1<\/td>\n<td>2-8 bar<\/td>\n<td>400XP<sub>L<\/sub><\/td>\n<td>3200<\/td>\n<td>NPT1\/4<\/td>\n<td>M14X1.5<\/td>\n<td>0.48<\/td>\n<\/tr>\n<tr>\n<td>DGG510<\/td>\n<td>510:1<\/td>\n<td>2-8 bar<\/td>\n<td>510XP<sub>L<\/sub><\/td>\n<td>4080<\/td>\n<td>NPT1\/4<\/td>\n<td>M14X1.5<\/td>\n<td>0.65<\/td>\n<\/tr>\n<tr>\n<td>DGG800<\/td>\n<td>800:1<\/td>\n<td>2-8 bar<\/td>\n<td>800XP<sub>L<\/sub><\/td>\n<td>6400<\/td>\n<td>NPT1\/4<\/td>\n<td>M14X1.5<\/td>\n<td>0.42<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The outlet liquid pressure=Driven air pressure*boost ratio<br \/>In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar<\/p>\n<p><strong>DGGD Series Liquid Pumps(Double acting, single air drive head)<\/strong><br \/>They are characterized by the same features as the DGG pumps single acting, single air drive head types, <br \/>but they have less pulsations and deliver approx. 50 % more flow.<\/p>\n<p><strong>Technical specification<\/strong><br \/>\u00a0<\/p>\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Pressure\u00a0 Boost Ratio<\/td>\n<td>Driven air pressure P<sub>L<\/sub> <\/td>\n<td>Formula to calculate outlet pressure<\/td>\n<td>MAX Outlet<br \/>Pressure(bar)*<\/td>\n<td>Liquid inlet Connection<\/td>\n<td>Liquid outlet Connection<\/td>\n<td>MAX Flow (L\/min)**<\/td>\n<\/tr>\n<tr>\n<td>DGGD4<\/td>\n<td>4:1<\/td>\n<td>2-8 bar<\/td>\n<td>4XP<sub>L<\/sub><\/td>\n<td>32<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>70.00<\/td>\n<\/tr>\n<tr>\n<td>DGGD6<\/td>\n<td>6:1<\/td>\n<td>2-8 bar<\/td>\n<td>6XP<sub>L<\/sub><\/td>\n<td>48<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>48.60<\/td>\n<\/tr>\n<tr>\n<td>DGGD10<\/td>\n<td>10:1<\/td>\n<td>2-8 bar<\/td>\n<td>10XP<sub>L<\/sub><\/td>\n<td>80<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>30.61<\/td>\n<\/tr>\n<tr>\n<td>DGGD16<\/td>\n<td>16:1<\/td>\n<td>2-8 bar<\/td>\n<td>16XP<sub>L<\/sub><\/td>\n<td>128<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>19.73<\/td>\n<\/tr>\n<tr>\n<td>DGGD28<\/td>\n<td>28:1<\/td>\n<td>2-8 bar<\/td>\n<td>28XP<sub>L<\/sub><\/td>\n<td>224<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT1\/2<\/td>\n<td>11.30<\/td>\n<\/tr>\n<tr>\n<td>DGGD40<\/td>\n<td>40:1<\/td>\n<td>2-8 bar<\/td>\n<td>40XP<sub>L<\/sub><\/td>\n<td>320<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT3\/8<\/td>\n<td>7.69<\/td>\n<\/tr>\n<tr>\n<td>DGGD64<\/td>\n<td>64:1<\/td>\n<td>2-8 bar<\/td>\n<td>64XP<sub>L<\/sub><\/td>\n<td>512<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT3\/8<\/td>\n<td>4.94<\/td>\n<\/tr>\n<tr>\n<td>DGGD80<\/td>\n<td>80:1<\/td>\n<td>2-8 bar<\/td>\n<td>80XP<sub>L<\/sub><\/td>\n<td>640<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT3\/8<\/td>\n<td>3.96<\/td>\n<\/tr>\n<tr>\n<td>DGGD100<\/td>\n<td>100:1<\/td>\n<td>2-8 bar<\/td>\n<td>100XP<sub>L<\/sub><\/td>\n<td>800<\/td>\n<td>NPT1\/2<\/td>\n<td>NPT3\/8<\/td>\n<td>3.13<\/td>\n<\/tr>\n<tr>\n<td>DGGD130<\/td>\n<td>130:1<\/td>\n<td>2-8 bar<\/td>\n<td>130XP<sub>L<\/sub><\/td>\n<td>1040<\/td>\n<td>NPT1\/2<\/td>\n<td>M14*1.5<\/td>\n<td>2.40<\/td>\n<\/tr>\n<tr>\n<td>DGGD175<\/td>\n<td>175:1<\/td>\n<td>2-8 bar<\/td>\n<td>175XP<sub>L<\/sub><\/td>\n<td>1400<\/td>\n<td>NPT3\/8<\/td>\n<td>M14*1.5<\/td>\n<td>1.81<\/td>\n<\/tr>\n<tr>\n<td>DGGD255<\/td>\n<td>255:1<\/td>\n<td>2-8 bar<\/td>\n<td>255XP<sub>L<\/sub><\/td>\n<td>2040<\/td>\n<td>NPT1\/4<\/td>\n<td>M14*1.5<\/td>\n<td>1.23<\/td>\n<\/tr>\n<tr>\n<td>DGGD400<\/td>\n<td>400:1<\/td>\n<td>2-8 bar<\/td>\n<td>400XP<sub>L<\/sub><\/td>\n<td>3200<\/td>\n<td>NPT1\/4<\/td>\n<td>M14*1.5<\/td>\n<td>0.79<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The outlet liquid pressure=Driven air pressure*boost ratio<br \/>In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar<\/p>\n<p><strong>Suncenter CZPT  Series CZPT  (Air driven) Liquid Booster System <\/strong><br \/><strong>Suncenter- CZPT  Series CZPT <\/strong><strong>(Air driven) CZPT ulic CZPT  Packs<\/strong><strong> <\/strong><br \/>SUNCENTER- CZPT ulic CZPT  packs(Liquid pump system) are compact and delicacy solution tailored to CZPT er specific requirements with air driven liquid pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.<br \/>To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. CZPT  CZPT ulic CZPT  packs are CZPT  with wide range of pressure ratios make these series of pumps ideal for CZPT ing a variety of oil\/hydraulic operations. The maximum operating pressure up to 640 MPa. <br \/>As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven liquid pump have to be equipped with\u00a0the air control unit\u00a0combined filter and water separator, pressure-regulating valve, pressure control gauge as well as\u00a0manual relieve valve. In this operation, the pump will be mounted\u00a0to the\u00a0stainless steel\u00a0tank in the closed cabinet\u00a0in a compact and space saving manner. Pressure gauges, valves and pressure regulators\u00a0will be fitted on panel. <br \/>The desired operating pressure can be attained by adjusting the driving air pressure. When the driving air pressure and the output pressure reach the balance, the pump stops filling pressure and the output pressure stays at the preset value. This hydraulic unit can be used for all kinds of pressure testing and test tools for research and test institutes or for other functions requiring a determined pressure.\u00a0<\/p>\n<p>HangZhou CZPT center CZPT  Control Equipment Co., Ltd is the member company of CZPT center CZPT , which is located in HangZhou city of ZheJiang   province in CZPT . With more than 15 years experiences in fluid pressure exchange and controlling field, we provide CZPT  kinds of pneumatic and hydraulic booster pumps, systems and solutions to the CZPT ers all over the world. Due to CZPT  best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.<br \/>\u00a0<br \/><strong>Our main products including:<\/strong><br \/>High Pressure Booster Pumps (Air CZPT n Gas Booster Pump, Air CZPT n Liquid Pump, Air Amplifiers)<br \/>High Pressure Systems (Gas\/Liquid Booster Stations,FM200 filling machine, Tube Expanding CZPT )<br \/>High Pressure Test Equipment(Hydraulic\/Burst\/Hydrostatic test machine,Cylinder test machine,<br \/>Valve test bench,Impulse Testing CZPT , etc.)<br \/>\u00a0<br \/><strong>Product Application<\/strong><br \/>Oil Industry, Gas Industry, CZPT  Industry, CZPT  Fighting, Research Institutions etc.<br \/>\u00a0<br \/><strong>Our service<\/strong><br \/>13 months&#8217; free warranty since the purchasing date and free technical support during lifetime<\/p>\n<p>\u00a0                <\/p>\n<p>\n<p>\n<p>\n<img decoding=\"async\" src=\"https:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-4.jpg\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Product Description Suncenter pneumatic hydraulic piston pumpWe offer the most complete range of Air driven liquid pump models in the industry measured for: Capability of ultimate pressure, flow or output horsepower. Compatibility with a broad variety of liquids, such as oil, water and chemical applications. SUNCENTER pumps are air driven at a drive air pressure [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[5],"tags":[49,414,385,386,417,1037,1076,751,1038],"class_list":["post-1823","post","type-post","status-publish","format-standard","hentry","category-product-catalog","tag-hydraulic","tag-hydraulic-piston-pump","tag-hydraulic-pump","tag-hydraulic-pump-pump","tag-piston-hydraulic","tag-piston-hydraulic-pump","tag-pneumatic-hydraulic-pump","tag-price-hydraulic","tag-pump-hydraulic-piston"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/1823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/comments?post=1823"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/1823\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/media?parent=1823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/categories?post=1823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/tags?post=1823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}