{"id":467,"date":"2020-10-11T07:12:26","date_gmt":"2020-10-11T07:12:26","guid":{"rendered":"https:\/\/pistonpumps.top\/hydraulic-piston-pump-a4vso250-for-industrial-application\/"},"modified":"2020-10-11T07:12:26","modified_gmt":"2020-10-11T07:12:26","slug":"hydraulic-piston-pump-a4vso250-for-industrial-application","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/en_au\/hydraulic-piston-pump-a4vso250-for-industrial-application\/","title":{"rendered":"Hydraulic Piston Pump A4vso250 for Industrial Application"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Hydraulic Piston Pump A4vso250 for Industrial Application\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Hydraulic Piston Pump A4vso250 for Industrial Application\" \/><\/p>\n<p><p>                                    <strong>CZPT\u00a0A4VSO of A4VSO40,A4VSO71,A4VSO125,A4VSO180,A4VSO250<\/strong><br \/>\u00a0<\/p>\n<p><strong>A4VSO variable pump functions:<\/strong><br \/>one.Axial plunger variable pump with tilting disc structure for hydrostatic travel in open circuit<br \/>2. flow charge is proportional to transmission pace and displacement<br \/>3. the stepless adjust of stream can be recognized by modifying the Angle of rotating inclined disk.<br \/>four. two shell drain outlets<br \/>five.exceptional oil absorption performance<br \/>six. low sounds stage<br \/>7.Prolonged service existence<br \/>eight. axial and radial load potential of the transmission shaft<br \/>9. ideal power fat ratio<br \/>10. Multiple control locations<br \/>11.limited control time<br \/>twelve.The pump is driven by a by means of shaft and can be mounted with a gear pump or significantly less than or equal to the identical specification,the axial plunger pump is 100% via shaft driven.<\/p>\n<p><strong>CZPT Knowledge:<\/strong><br \/>\u00a0<\/p>\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n<tbody>\n<tr>\n<td colspan=\"8\">Nominal dimensions<\/td>\n<td>A4VSO40<\/td>\n<td>A4VSO71<\/td>\n<td>A4VSO125<\/td>\n<td>A4VSO180<\/td>\n<td>A4VSO250<\/td>\n<\/tr>\n<tr>\n<td>Nominal force<\/td>\n<td>p\u00a0N<\/td>\n<td colspan=\"6\">bar<\/td>\n<td>350<\/td>\n<td>350<\/td>\n<td>350<\/td>\n<td>350<\/td>\n<td>350<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Greatest stress<\/td>\n<td>pmax<\/td>\n<td colspan=\"5\">bar<\/td>\n<td>450<\/td>\n<td>450<\/td>\n<td>450<\/td>\n<td>450<\/td>\n<td>450<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Displacement<\/td>\n<td>Vg\u00a0max<\/td>\n<td colspan=\"5\">cm\u00b3<\/td>\n<td>40<\/td>\n<td>71<\/td>\n<td>a hundred twenty five<\/td>\n<td>a hundred and eighty<\/td>\n<td>250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Pace<\/td>\n<td>Max. pace<\/td>\n<td>n\u00a0max<\/td>\n<td colspan=\"4\">rpm<\/td>\n<td>2200<\/td>\n<td>2200<\/td>\n<td>1800<\/td>\n<td>1800<\/td>\n<td>1500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Movement<\/td>\n<td>at\u00a0n\u00a0max<\/td>\n<td>q\u00a0V max<\/td>\n<td colspan=\"3\">l\/min<\/td>\n<td>156<\/td>\n<td>156<\/td>\n<td>225<\/td>\n<td>324<\/td>\n<td>375<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Power<\/td>\n<td colspan=\"2\">\u0394\u00a0p\u00a0= 350 bar<\/td>\n<td>P\u00a0max<\/td>\n<td colspan=\"2\">kw<\/td>\n<td>ninety one<\/td>\n<td>ninety one<\/td>\n<td>131<\/td>\n<td>189<\/td>\n<td>219<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Torque<\/td>\n<td colspan=\"2\">\u0394 p = 350 bar\u00a0<\/td>\n<td>CZPT<\/td>\n<td>Nm<\/td>\n<td>395<\/td>\n<td>395<\/td>\n<td>696<\/td>\n<td>1002<\/td>\n<td>1391<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><p><strong>Images:<\/p>\n<p><\/strong><\/p>\n<p>\u00a0<\/p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"Hydraulic Piston Pump A4vso250 for Industrial Application\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Hydraulic Piston Pump A4vso250 for Industrial Application\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>CZPT\u00a0A4VSO of A4VSO40,A4VSO71,A4VSO125,A4VSO180,A4VSO250\u00a0 A4VSO variable pump functions:one.Axial plunger variable pump with tilting disc structure for hydrostatic travel in open circuit2. flow charge is proportional to transmission pace and displacement3. the stepless adjust of stream can be recognized by modifying the Angle of rotating inclined disk.four. two shell drain outletsfive.exceptional oil absorption performancesix. low sounds stage7.Prolonged [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[802,49,414,385,386,417],"class_list":["post-467","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-application","tag-hydraulic","tag-hydraulic-piston-pump","tag-hydraulic-pump","tag-hydraulic-pump-pump","tag-piston-hydraulic"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/467","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/comments?post=467"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/467\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/media?parent=467"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/categories?post=467"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/tags?post=467"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}