{"id":765,"date":"2020-10-12T11:48:54","date_gmt":"2020-10-12T11:48:54","guid":{"rendered":"https:\/\/pistonpumps.top\/oil-lubrication-negative-pressure-suction-station-for-small-hosptial\/"},"modified":"2020-10-12T11:48:54","modified_gmt":"2020-10-12T11:48:54","slug":"oil-lubrication-negative-pressure-suction-station-for-small-hosptial","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/en_au\/oil-lubrication-negative-pressure-suction-station-for-small-hosptial\/","title":{"rendered":"Oil Lubrication Negative Pressure Suction Station for Small Hosptial"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Oil Lubrication Negative Pressure Suction Station for Small Hosptial\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Oil Lubrication Negative Pressure Suction Station for Small Hosptial\" \/><\/p>\n<p>\n<p><strong>Oil CZPT Negative Stress Suction Station For Small Hosptial Or Clinic<\/strong><br \/>\u00a0<\/p>\n<p>\n<p><p><strong>1. ETR Oil CZPT Kind Hospital Vacuum Suction Method Description<\/strong><\/p>\n<p><p>ETR has independently created an built-in vacuum pump unit composed of a oil lubrication vacuum pump,\u00a0 a vacuum solenoid valve, pipe fittings and an electrical handle technique. It is a basic, secure and dependable gadget that constantly serves the wards all working day long, with no occupying the ward place. The adverse stress is sourced from the vacuum pump unit.<\/p>\n<p>\u00a0<\/p>\n<p><p><strong>two.<\/strong><strong>Edge<\/strong><\/p>\n<p><p>one. Oil lubrication vacuum pump, substantial effectiveness, low noise, steady and reliable procedure<br \/>two. Integrated modular style, modest footprint and flexible area<br \/>three. Complete touch display screen management and operation, intelligent management, totally computerized procedure and switching<br \/>four. Adverse pressure selection: &#8211; .07MPa~ -.03 Mpa<br \/>\u00a0<\/p>\n<p>\n<p><strong>3. <\/strong><strong>Functioning Principle<br \/><\/strong><br \/><strong>4. <\/strong> <strong>Product For Assortment<\/strong><\/p>\n<p>\n<table>\n<colgroup>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr>\n<td rowspan=\"2\">Product<\/td>\n<td rowspan=\"2\">Capaticy<br \/>(m3\/h)<\/td>\n<td rowspan=\"2\">Max Strain<br \/>hpa(mbar)<\/td>\n<td rowspan=\"2\">Inlet\/Outlet Force<\/td>\n<td rowspan=\"2\">CZPT<br \/>Voltage<\/td>\n<td rowspan=\"2\">Energy<br \/>(KW)<\/td>\n<td rowspan=\"2\">Width<br \/>(MM)<\/td>\n<td rowspan=\"2\">Length<br \/>(MM)<\/td>\n<td rowspan=\"2\">Height<br \/>(MM)<\/td>\n<td rowspan=\"2\">Excess weight<br \/>(KG)<\/td>\n<td rowspan=\"2\">Sound<br \/>dB(A)<\/td>\n<td rowspan=\"2\">Tank<br \/>(m3)<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td>ETV-02<\/td>\n<td>60X2<\/td>\n<td>.1<\/td>\n<td>G11\/4&#8243;(DN32)<\/td>\n<td>AC380V\/50Hz\/3P<\/td>\n<td>one.5X2<\/td>\n<td>670<\/td>\n<td>1571<\/td>\n<td>880\/1470<\/td>\n<td>500<\/td>\n<td>\u226472<\/td>\n<td>1.0\u00a0<\/td>\n<\/tr>\n<tr>\n<td>ETV-03<\/td>\n<td>100X2<\/td>\n<td>.one<\/td>\n<td>G11\/four&#8221;(DN32)<\/td>\n<td>AC380V\/50Hz\/3P<\/td>\n<td>three.0X2<\/td>\n<td>670<\/td>\n<td>1080<\/td>\n<td>880\/1470<\/td>\n<td>600<\/td>\n<td>\u226472<\/td>\n<td>one.0\u00a0<\/td>\n<\/tr>\n<tr>\n<td>ETV-04<\/td>\n<td>160X2<\/td>\n<td>.1<\/td>\n<td>G2&#8243;(DN50)<\/td>\n<td>AC380V\/50Hz\/3P<\/td>\n<td>four.0X2<\/td>\n<td>740<\/td>\n<td>1220<\/td>\n<td>1571\/1720<\/td>\n<td>680<\/td>\n<td>\u226472<\/td>\n<td>1.5\u00a0<\/td>\n<\/tr>\n<tr>\n<td>ETV-05<\/td>\n<td>250X2<\/td>\n<td>.one<\/td>\n<td>G2&#8243;(DN50)<\/td>\n<td>AC380V\/50Hz\/3P<\/td>\n<td>five.5X2<\/td>\n<td>740<\/td>\n<td>1250<\/td>\n<td>1571\/1800<\/td>\n<td>seven-hundred<\/td>\n<td>\u226472<\/td>\n<td>one.5\u00a0<\/td>\n<\/tr>\n<tr>\n<td>ETV-07<\/td>\n<td>300X2<\/td>\n<td>.1<\/td>\n<td>G2&#8243;(DN50)<\/td>\n<td>AC380V\/50Hz\/3P<\/td>\n<td>7.5X2<\/td>\n<td>800<\/td>\n<td>1400<\/td>\n<td>1571\/1800<\/td>\n<td>800<\/td>\n<td>\u226472<\/td>\n<td>2.0\u00a0<\/td>\n<\/tr>\n<tr>\n<td>ETV-eleven<\/td>\n<td>250X4<\/td>\n<td>.1<\/td>\n<td>G3&#8243;(DN65)<\/td>\n<td>AC380V\/50Hz\/3P<\/td>\n<td>five.5X4<\/td>\n<td>1500<\/td>\n<td>1150<\/td>\n<td>1150<\/td>\n<td>1500<\/td>\n<td>\u226473<\/td>\n<td>3.0\u00a0<\/td>\n<\/tr>\n<tr>\n<td>ETV-fifteen<\/td>\n<td>300X4<\/td>\n<td>.one<\/td>\n<td>G4&#8243;(DN100)<\/td>\n<td>AC380V\/50Hz\/3P<\/td>\n<td>seven.5X4<\/td>\n<td>1600<\/td>\n<td>1800<\/td>\n<td>1300<\/td>\n<td>1960<\/td>\n<td>\u226473<\/td>\n<td>four.0\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><p>\u00a0<\/p>\n<p><strong>5<\/strong><strong><strong>.<\/strong> Guarantee &amp;Services<\/strong><\/p>\n<p><strong>Warranty<\/strong><br \/>The Promise\/Guarantee Period of time shall be a period of twelve months after on-site startup &amp; commissioning or eighteen months after shipment, whichever happens initial.\u00a0If any trouble or defect, originating with the design and style, substance, workmanship or functioning traits of any Items, occurs at any time throughout warranty period, ETR shall, at his own cost and as immediately as feasible, make these kinds of alterations, repairs and replacements.<\/p>\n<p><strong>On-Web site Support<\/strong><br \/>ETR can do paid providers of on-web site startup, commissioning, set up supervision, coaching, by providing purchaser with the companies of qualified\u00a0English-speaking<br \/>engineer at internet site.\u00a0ETR\u00a0shall receive all permits and licenses essential to execute the services underneath this Agreement.<\/p>\n<p><strong><strong>Organization OVERVIEW<\/strong><\/strong><\/p>\n<p><strong><strong>one.Fundamental Details about ETR<\/strong><\/strong><\/p>\n<p><strong>Manufacturing unit<\/strong><\/p>\n<p><strong>CZPT web site<\/strong><\/p>\n<p>\u00a0<\/p>\n<p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"Oil Lubrication Negative Pressure Suction Station for Small Hosptial\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Oil Lubrication Negative Pressure Suction Station for Small Hosptial\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Oil CZPT Negative Stress Suction Station For Small Hosptial Or Clinic\u00a0 1. ETR Oil CZPT Kind Hospital Vacuum Suction Method Description ETR has independently created an built-in vacuum pump unit composed of a oil lubrication vacuum pump,\u00a0 a vacuum solenoid valve, pipe fittings and an electrical handle technique. It is a basic, secure and dependable [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-765","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/comments?post=765"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/posts\/765\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/media?parent=765"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/categories?post=765"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/en_au\/wp-json\/wp\/v2\/tags?post=765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}