{"id":1289,"date":"2020-10-15T17:35:37","date_gmt":"2020-10-15T17:35:37","guid":{"rendered":"https:\/\/pistonpumps.top\/custom-large-size-vertical-single-stage-double-volute-suction-split-case-pump-for-farm-irrigation\/"},"modified":"2020-10-15T17:35:37","modified_gmt":"2020-10-15T17:35:37","slug":"custom-large-size-vertical-single-stage-double-volute-suction-split-case-pump-for-farm-irrigation","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/es\/custom-large-size-vertical-single-stage-double-volute-suction-split-case-pump-for-farm-irrigation\/","title":{"rendered":"Custom Large Size Vertical Single Stage Double Volute Suction Split Case Pump for Farm Irrigation"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Custom Large Size Vertical Single Stage Double Volute Suction Split Case Pump for Farm Irrigation\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Custom Large Size Vertical Single Stage Double Volute Suction Split Case Pump for Farm Irrigation\" \/><\/p>\n<p><p><strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 MS Split circumstance pump<\/strong><\/p>\n<p><strong>MS type Break up casing drinking water pump<\/strong> 1000 cubic meter for every hour is a Break up casing h2o pump. It is used<br \/>totransport pure h2o and the liquid which actual physical and chemical character is comparable with h2o<br \/>themaximum temperature isn&#8217;t much more than eighty \u00baC.<br \/><strong>This sequence of pump is suitable for h2o offer and drainage in factories, mines and metropolitan areas,<br \/>electricity station, drainage and irrigation of farming, and types of hydraulic initiatives.<\/strong><\/p>\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td>Dise\u00f1o<\/td>\n<td>Entrada\/Salida<br \/>(mil\u00edmetros)<\/td>\n<td>Potencial<br \/>m\u00b3\/h<\/td>\n<td>Cabeza<br \/>metro<\/td>\n<td>Velocidad<br \/>(rpm)<\/td>\n<td>Potencia el\u00e9ctrica del eje (kW)<\/td>\n<\/tr>\n<tr>\n<td>200S-noventa y cinco<\/td>\n<td>two hundred\/200<\/td>\n<td>280<\/td>\n<td>95<\/td>\n<td>2900<\/td>\n<td>94<\/td>\n<\/tr>\n<tr>\n<td>200S-sesenta y tres<\/td>\n<td>doscientos\/doscientos<\/td>\n<td>280<\/td>\n<td>sesenta y tres<\/td>\n<td>2900<\/td>\n<td>fifty nine.3<\/td>\n<\/tr>\n<tr>\n<td>200S-forty two<\/td>\n<td>200\/doscientos<\/td>\n<td>280<\/td>\n<td>42<\/td>\n<td>2900<\/td>\n<td>37.7<\/td>\n<\/tr>\n<tr>\n<td>250S-sesenta y cinco<\/td>\n<td>250\/250<\/td>\n<td>485<\/td>\n<td>sesenta y cinco<\/td>\n<td>1450<\/td>\n<td>108.siete<\/td>\n<\/tr>\n<tr>\n<td>250S-39<\/td>\n<td>250\/250<\/td>\n<td>485<\/td>\n<td>39<\/td>\n<td>1450<\/td>\n<td>62.one<\/td>\n<\/tr>\n<tr>\n<td>250S-24<\/td>\n<td>250\/250<\/td>\n<td>485<\/td>\n<td>24<\/td>\n<td>1450<\/td>\n<td>36.9<\/td>\n<\/tr>\n<tr>\n<td>250S-fourteen<\/td>\n<td>250\/250<\/td>\n<td>485<\/td>\n<td>catorce<\/td>\n<td>1450<\/td>\n<td>21.7<\/td>\n<\/tr>\n<tr>\n<td>300S-90<\/td>\n<td>300\/trescientos<\/td>\n<td>790<\/td>\n<td>90<\/td>\n<td>1450<\/td>\n<td>249.8<\/td>\n<\/tr>\n<tr>\n<td>300S-58<\/td>\n<td>300\/300<\/td>\n<td>790<\/td>\n<td>58<\/td>\n<td>1450<\/td>\n<td>148.5<\/td>\n<\/tr>\n<tr>\n<td>300S-32<\/td>\n<td>300\/300<\/td>\n<td>790<\/td>\n<td>32<\/td>\n<td>1450<\/td>\n<td>79<\/td>\n<\/tr>\n<tr>\n<td>300S-19<\/td>\n<td>300\/trescientos<\/td>\n<td>790<\/td>\n<td>19<\/td>\n<td>1450<\/td>\n<td>forty six.9<\/td>\n<\/tr>\n<tr>\n<td>300S-12<\/td>\n<td>three hundred\/300<\/td>\n<td>790<\/td>\n<td>doce<\/td>\n<td>1450<\/td>\n<td>31.uno<\/td>\n<\/tr>\n<tr>\n<td>350S-125<\/td>\n<td>350\/350<\/td>\n<td>1260<\/td>\n<td>ciento veinticinco<\/td>\n<td>1450<\/td>\n<td>531<\/td>\n<\/tr>\n<tr>\n<td>350S-75<\/td>\n<td>350\/350<\/td>\n<td>1260<\/td>\n<td>75<\/td>\n<td>1450<\/td>\n<td>304<\/td>\n<\/tr>\n<tr>\n<td>350S-44<\/td>\n<td>350\/350<\/td>\n<td>1260<\/td>\n<td>cuarenta y cuatro<\/td>\n<td>1450<\/td>\n<td>177.6<\/td>\n<\/tr>\n<tr>\n<td>350S-26<\/td>\n<td>350\/350<\/td>\n<td>1260<\/td>\n<td>26<\/td>\n<td>1450<\/td>\n<td>one zero one.five<\/td>\n<\/tr>\n<tr>\n<td>350S-sixteen<\/td>\n<td>350\/350<\/td>\n<td>1260<\/td>\n<td>diecis\u00e9is<\/td>\n<td>1450<\/td>\n<td>63.eight<\/td>\n<\/tr>\n<tr>\n<td>500S-thirteen<\/td>\n<td>500\/500<\/td>\n<td>2571<\/td>\n<td>13<\/td>\n<td>980<\/td>\n<td>86.two<\/td>\n<\/tr>\n<tr>\n<td>500S-35<\/td>\n<td>500\/500<\/td>\n<td>2571<\/td>\n<td>35<\/td>\n<td>980<\/td>\n<td>219<\/td>\n<\/tr>\n<tr>\n<td>500S-98<\/td>\n<td>500\/500<\/td>\n<td>2571<\/td>\n<td>98<\/td>\n<td>980<\/td>\n<td>678<\/td>\n<\/tr>\n<tr>\n<td>600S22<\/td>\n<td>600\/600<\/td>\n<td>3241<\/td>\n<td>22<\/td>\n<td>980<\/td>\n<td>231.eight<\/td>\n<\/tr>\n<tr>\n<td>600S75<\/td>\n<td>600\/600<\/td>\n<td>3060<\/td>\n<td>75<\/td>\n<td>980<\/td>\n<td>694.cuatro<\/td>\n<\/tr>\n<tr>\n<td>800S32<\/td>\n<td>800\/800<\/td>\n<td>5500<\/td>\n<td>32<\/td>\n<td>730<\/td>\n<td>538.5<\/td>\n<\/tr>\n<tr>\n<td>800S47<\/td>\n<td>800\/800<\/td>\n<td>5500<\/td>\n<td>47<\/td>\n<td>730<\/td>\n<td>782.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Modo Pump Co.,Ltd. is one particular in excess of thirty several years experienced pump producer (set up at 1986) in<br \/>mining and mineral, electrical power plant, dredging and dredge, hydraulic, irrigation, pulp transfer, chemical,<br \/>development, sea water and oil &amp; gasoline transfer and many others. Modo Pump Co.,Ltd. is the pump factory has its<br \/>personal pump variety &amp; layout, research and development team to assure supply you successful, energy<br \/>Bombas de lodos, bombas de agua, bombas de agua di\u00e9sel, bombas qu\u00edmicas y bombas de riego en surtido<br \/>&amp; design and style, use and routine maintenance plan. Our items contain slurry pump, sewage pump, h2o<br \/>pump, acid resistant or chemical pump, irrigation pumps, fire pumps and other items exported to<br \/>in excess of ninety nations around the world all above the world. The application addresses several fields, this kind of as mining and mineral<br \/>processing, dredger, tailings transportation, mining, steel, desulfurization pump, boiler feed h2o,<br \/>design, irrigation, drinking water conservancy amenities, sewage treatment method, drainage and drinking water provide.<\/p>\n<p><strong>1, What info is needed to provide a break up casing pump? <\/strong><br \/>L\u00edquido:___<br \/>Capacity:___ m3\/hr<br \/>Cabeza: ___ m<br \/>Voltaje:___V, Frecuencia:___Hz<br \/>\u00a0<\/p>\n<p><p><strong>two, What is the edge of split casing pump?<\/strong><br \/>Super procedure efficiency with big flow fee at large stress.<br \/>\u00a0<\/p>\n<p><p><strong>3, Can this split casing pump transfer sea drinking water? <\/strong><br \/>Yes, with St.st.316 or duplex 2205 substance.<br \/>\u00a0<\/p>\n<p><p><strong>four, Can you deliver the pump to our region?<\/strong><br \/>Of system. Please recommend the vacation spot port or your handle.<br \/>\u00a0<\/p>\n<p><p><strong>five, How extended is your guarantee?<\/strong><br \/>twelve months.<\/p>\n<p>\u00a0                            <\/p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"Custom Large Size Vertical Single Stage Double Volute Suction Split Case Pump for Farm Irrigation\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Custom Large Size Vertical Single Stage Double Volute Suction Split Case Pump for Farm Irrigation\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 MS Split circumstance pump MS type Break up casing drinking water pump 1000 cubic meter for every hour is a Break up casing h2o pump. It is usedtotransport pure h2o and the liquid which actual physical and [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1289","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/posts\/1289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/comments?post=1289"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/posts\/1289\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/media?parent=1289"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/categories?post=1289"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/es\/wp-json\/wp\/v2\/tags?post=1289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}