{"id":560,"date":"2020-10-11T14:25:14","date_gmt":"2020-10-11T14:25:14","guid":{"rendered":"https:\/\/pistonpumps.top\/vt-v6-h-low-voltage-vectol-control-torque-control-200v-400v-vfd-15-to-55kw\/"},"modified":"2020-10-11T14:25:14","modified_gmt":"2020-10-11T14:25:14","slug":"vt-v6-h-low-voltage-vectol-control-torque-control-200v-400v-vfd-15-to-55kw","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/ja\/vt-v6-h-low-voltage-vectol-control-torque-control-200v-400v-vfd-15-to-55kw\/","title":{"rendered":"V&amp;T V6-H \u4f4e\u96fb\u5727\u30d9\u30af\u30c8\u30eb\u5236\u5fa1\u30c8\u30eb\u30af\u5236\u5fa1 200V 400V VFD 15\uff5e55kW"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"V&amp;T V6-H \u4f4e\u96fb\u5727\u30d9\u30af\u30c8\u30eb\u5236\u5fa1\u30c8\u30eb\u30af\u5236\u5fa1 200V 400V VFD 15\uff5e55kW\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"V&amp;T V6-H Low Voltage Vectol Control  Torque Control 200V 400V VFD 15 to 55kw\" \/><\/p>\n<p><p>                                    V6-H\u30b3\u30ec\u30af\u30b7\u30e7\u30f3 \u30c8\u30eb\u30af\u5236\u5fa1\u30a4\u30f3\u30d0\u30fc\u30bf\u30fc\u306e\u7dcf\u5408\u6027\u80fd\u5411\u4e0a<\/p>\n<p>20\u5e74\u4ee5\u4e0a\u306b\u308f\u305f\u308a\u3001\u3055\u307e\u3056\u307e\u306a\u7523\u696d\u5206\u91ce\u304cV&amp;T\u306e\u8cbb\u7528\u5bfe\u52b9\u679c\u304c\u9ad8\u304f\u3001\u6a5f\u80fd\u6027\u3092\u91cd\u8996\u3057\u305fAC CZPT\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306e\u6069\u6075\u3092\u53d7\u3051\u3066\u304d\u307e\u3057\u305f\u3002V&amp;T\u306f\u5404\u696d\u754c\u306e\u5177\u4f53\u7684\u306a\u30cb\u30fc\u30ba\u3092\u6df1\u304f\u7406\u89e3\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u52a0\u5de5\u3001\u7e4a\u7dad\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3001\u30bb\u30e9\u30df\u30c3\u30af\u3001\u533b\u85ac\u54c1\u3001\u30a8\u30ec\u30d9\u30fc\u30bf\u30fc\u3001\u77f3\u6cb9\u30fb\u71c3\u6599\u3001\u96fb\u529b\u3001\u30bb\u30e1\u30f3\u30c8\u3001\u6750\u6599\u7ba1\u7406\u306a\u3069\u3001\u591a\u304f\u306e\u696d\u754c\u5411\u3051\u306b\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u56fa\u6709\u306e\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><strong>\u4e3b\u306a\u5c5e\u6027<\/strong><\/p>\n<p>1. \u54c1\u63c3\u3048\uff1a0.4kW\uff5e450kW<br \/>2. V\/F \u30cf\u30f3\u30c9\u30eb\u3001PG \u4ed8\u304d V\/F\u3001\u30b9\u30ea\u30c3\u30d7\u652f\u6255\u3044\u3001\u30bb\u30f3\u30b5\u30fc\u30ec\u30b9\u30d9\u30af\u30c8\u30eb\u5236\u5fa1\u3001\u30cb\u30a2\u30eb\u30fc\u30d7\u30d9\u30af\u30c8\u30eb\u5236\u5fa1<br \/>3. CZPT\u3068\u30a6\u30a9\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u5185\u8535CZPT<br \/>4. \u30a6\u30a3\u30f3\u30c0\u30fc\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2<br \/>5.CZPTing\u30c8\u30eb\u30af\u30010Hz\u3001\u30af\u30ed\u30fc\u30ba\u30c9\u30eb\u30fc\u30d7<br \/>6. \u30aa\u30d7\u30b7\u30e7\u30f3\u306e\u30b9\u30de\u30fc\u30c8PLC<br \/>7.\u81ea\u52d5\u30b7\u30fc\u30b1\u30f3\u30b9<br \/>8. \u30c9\u30ed\u30c3\u30d7\u7ba1\u7406<br \/>9. RS485 Modbus RTU \u306e\u76f8\u4e92\u4f5c\u7528\u3067\u4f5c\u6210\u3055\u308c\u307e\u3057\u305f\u3002<br \/>\u00a0<br \/>\u00a0<br \/><strong>\u88fd\u54c1\u306b\u3064\u3044\u3066 <\/strong><\/p>\n<p>V6-H\u30b7\u30ea\u30fc\u30ba\u306e\u30c8\u30eb\u30af\u5236\u5fa1\u30a4\u30f3\u30d0\u30fc\u30bf\u306f\u3001\u512a\u308c\u305fV\/F\u5236\u5fa1\u3001V\/F PG\u3001\u30b9\u30ea\u30c3\u30d7\u652f\u6255\u3044\u3001\u30bb\u30f3\u30b5\u30ec\u30b9\u30d9\u30af\u30c8\u30eb\u5236\u5fa1\u3001\u30af\u30ed\u30fc\u30ba\u30c9\u30eb\u30fc\u30d7\u30d9\u30af\u30c8\u30eb\u5236\u5fa1\u306a\u3069\u3001\u6570\u3005\u306e\u6a5f\u80fd\u3092\u901a\u3058\u3066\u5f37\u529b\u306a\u7dcf\u5408\u6027\u80fd\u3092\u767a\u63ee\u3057\u3001\u304a\u5ba2\u69d8\u306e\u7279\u5b9a\u306e\u30cb\u30fc\u30ba\u3092\u6e80\u305f\u3057\u307e\u3059\u3002<br \/>V6-H\u306f\u3001\u30af\u30ec\u30fc\u30f3\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u5dfb\u53d6\u6a5f\u3001\u9ad8\u901f\u30a8\u30ec\u30d9\u30fc\u30bf\u30fc\u3001\u30bb\u30e1\u30f3\u30c8\u30ad\u30eb\u30f3\u3001\u7834\u7815\u6a5f\u306a\u3069\u3001\u6700\u3082\u904e\u9177\u3067\u9ad8\u5ea6\u306a\u7528\u9014\u306b\u5b8c\u74a7\u306b\u9069\u5408\u3057\u307e\u3059\u3002\u6700\u5927450kW-Hd\/600kW-ND\u307e\u3067\u306e\u6570\u767e\u306e\u51fa\u529b\u306b\u5bfe\u5fdc\u3057\u3001\u30a4\u30f3\u30c9\u306e\u5de5\u696d\u5730\u5e2f\u7279\u6709\u306e\u9ad8\u6e29\u591a\u6e7f\u3067\u7c89\u5875\u306e\u591a\u3044\u74b0\u5883\u4e0b\u3067\u3082\u3001\u6a5f\u68b0\u304c\u6700\u9069\u306a\u52b9\u7387\u3067\u7a3c\u50cd\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><strong>\u30a2\u30d7\u30ea<\/strong><\/p>\n<p>1. CZPT\u30db\u30a4\u30b9\u30c8<br \/>2. CZPT &amp; \u30c6\u30ad\u30b9\u30bf\u30a4\u30eb CZPTs<br \/>3. CZPT\u4fdd\u5b58\u578bCZPT \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <br \/>4. CZPT<br \/>5. \u30b5\u30dd\u30fc\u30bf\u30fc\uff06\u30dd\u30f3\u30d7\uff0fCZPT\uff0fAHU\uff0f\u30d6\u30ed\u30ef\u30fc\u30de\u30b7\u30f3\uff0fID\uff0fFD\u30d5\u30a1\u30f3<br \/>6. CZPT\u5236\u5fa1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <br \/>7. \u98df\u6599\u54c1\u3068CZPT CZPT\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <br \/>8. AHU\u30cf\u30f3\u30c9\u30eb\u3002<\/p>\n<p>                            <\/p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"V&amp;T V6-H \u4f4e\u96fb\u5727\u30d9\u30af\u30c8\u30eb\u5236\u5fa1\u30c8\u30eb\u30af\u5236\u5fa1 200V 400V VFD 15\uff5e55kW\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"V&amp;T V6-H Low Voltage Vectol Control  Torque Control 200V 400V VFD 15 to 55kw\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>V6-H Collection higher overall performance torque control inverter For in excess of two a long time, different industry sectors have been reaping the rewards of V&amp;T&#8217;s cost-effective, functionality-oriented AC CZPT remedies. V&amp;T&#8217;s grasp of specific demands of every business allows it to provide software-specific remedies for numerous industries-such as processing ,textile, plastic, ceramic ,pharmaceutical, elevator, oil&amp; fuel, electricity, cement and materials-managing. Main Attributes 1.Assortment: .4kW to 450kWtwo.V\/F Handle, V\/F with PG, Slip Payment, Sensorless Vector Control, Near Loop Vector Manage3.Constructed-in CZPT for CZPT &amp; Wobbulation4.Winder Softwarefive.CZPTing Torque at one hundred eighty% at 0Hz for Close loopsix.Optional Smart PLCseven.Auto Sequenceeight.Droop Management9.Created-in RS485 Modbus RTU Interaction.\u00a0\u00a0About the Product V6-H series torque handle [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-560","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/posts\/560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/comments?post=560"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/posts\/560\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/media?parent=560"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/categories?post=560"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/ja\/wp-json\/wp\/v2\/tags?post=560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}