{"id":1618,"date":"2022-03-25T21:01:55","date_gmt":"2022-03-25T21:01:55","guid":{"rendered":"https:\/\/pistonpumps.top\/rexroth-cheap-a10vso-hydraulic-piston-pump-with-ce-certificate-top-quality-low-price\/"},"modified":"2022-03-25T21:01:55","modified_gmt":"2022-03-25T21:01:55","slug":"rexroth-cheap-a10vso-hydraulic-piston-pump-with-ce-certificate-top-quality-low-price","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/ko\/rexroth-cheap-a10vso-hydraulic-piston-pump-with-ce-certificate-top-quality-low-price\/","title":{"rendered":"\ub809\uc2a4\ub85c\uc2a4 A10vso \uc720\uc555 \ud53c\uc2a4\ud1a4 \ud38c\ud504, CE \uc778\uc99d, \ucd5c\uace0 \ud488\uc9c8, \uc800\ub834\ud55c \uac00\uaca9"},"content":{"rendered":"<p>\n<h2>\uc81c\ud488 \uc124\uba85<\/h2>\n<p>\n<p>                        \ubaa8\ub378:<br \/><strong>Rexroth piston pump &amp; motor<br \/>A10VSO Side Port Series 16\/18\/28\/45\/71\/100\/140<\/strong><br \/>Operating pressure range &#8211; inlet:<br \/>Absolute pressure at port S<br \/>Palx min &#8212;&#8212;&#8212;-0.8 bar<br \/>Palx max &#8212;&#8212;&#8212;-30 bar<\/p>\n<p>Operating pressure range &#8211; outlet:<br \/>Pressing at port B<br \/>Nominal pressure Pn&#8212;&#8212;&#8212;-280 bar<br \/>Peak pressure Pmax&#8212;&#8212;&#8212;-350 bar<br \/>Application with intermittent operating pressures up to 315 bar at 10% duty are permissible.<\/p>\n<p>\ud2b9\uc9d5:<br \/>1 for open-loop Swashplate axial piston pump.<br \/>2 continuous working pressure up to 280bar, the instantaneous maximum working pressure up to 350bar.<br \/>3 flow is proportional to drive speed and displacement, and can be achieved by adjusting the swashplate angle stepless variable.<br \/>4 there is constant pressure, constant-power constant pressure, constant-voltage constant-flow and other control method, and the control response speed.<br \/>5 Low-noise, high efficiency, high reliability, CZPT  life.<br \/>6 small size, high CZPT  density<br \/>7 excellent oil absorption properties.<br \/>8 drive shaft can withstand the axial and radial loads.<br \/>9 SAE and ISO mounting flange.<br \/>10 for pass-axis structure, and for multi-loop system.<\/p>\n<p>PERFORMANCE<\/p>\n<table>\n<tbody>\n<tr>\n<td>\ud06c\uae30<\/td>\n<td colspan=\"3\"><\/td>\n<td>18<\/td>\n<td>28<\/td>\n<td>45<\/td>\n<td>71<\/td>\n<td>100<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<td>\ubc30\uc218\ub7c9<\/td>\n<td colspan=\"3\">\ub2e4\uc12f<sub>g \ucd5c\ub300 <\/sub>cm 3<\/td>\n<td>18<\/td>\n<td>28<\/td>\n<td>45<\/td>\n<td>71<\/td>\n<td>100<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<td>\ucd5c\ub300 \uc18d\ub3c4<\/td>\n<td colspan=\"3\">N<sub>\ucd5c\ub300<\/sub>\ubd84\ub2f9 \ud68c\uc804\uc218<\/td>\n<td>3300<\/td>\n<td>3000<\/td>\n<td>2600<\/td>\n<td>2200<\/td>\n<td>2000<\/td>\n<td>1800<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\ucd5c\ub300 \uc720\ub7c9<\/td>\n<td>in n<sub>\ucd5c\ub300<\/sub><\/td>\n<td rowspan=\"2\">qv<\/td>\n<td rowspan=\"2\">\ub9ac\ud130\/\ubd84<\/td>\n<td>59.4<\/td>\n<td>84<\/td>\n<td>117<\/td>\n<td>156<\/td>\n<td>200<\/td>\n<td>252<\/td>\n<\/tr>\n<tr>\n<td>in1500r\/min<\/td>\n<td>27<\/td>\n<td>42<\/td>\n<td>68<\/td>\n<td>107<\/td>\n<td>150<\/td>\n<td>210<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Max. CZPT \u00a0 \u00a0 \u00a0 (280BAR)<\/td>\n<td>in n<sub>\ucd5c\ub300<\/sub><\/td>\n<td rowspan=\"2\">\ud53c<sub>\ucd5c\ub300<\/sub><\/td>\n<td rowspan=\"2\">\ucf70<\/td>\n<td>27.7<\/td>\n<td>39<\/td>\n<td>55<\/td>\n<td>73<\/td>\n<td>93<\/td>\n<td>118<\/td>\n<\/tr>\n<tr>\n<td>in1500r\/min<\/td>\n<td>12.6<\/td>\n<td>20<\/td>\n<td>32<\/td>\n<td>50<\/td>\n<td>70<\/td>\n<td>98<\/td>\n<\/tr>\n<tr>\n<td>Max. torque\u00a0 \u00a0 (280BAR)<\/td>\n<td>in V<sub>g \ucd5c\ub300<\/sub><\/td>\n<td>\ud2f0<sub>\ucd5c\ub300<\/sub><\/td>\n<td>Nm<\/td>\n<td>80.1<\/td>\n<td>125<\/td>\n<td>200<\/td>\n<td>316<\/td>\n<td>445<\/td>\n<td>623<\/td>\n<\/tr>\n<tr>\n<td>\ubb34\uac8c<\/td>\n<td><\/td>\n<td>\uc911<\/td>\n<td>\ud0ac\ub85c\uadf8\ub7a8<\/td>\n<td>12<\/td>\n<td>15<\/td>\n<td>21<\/td>\n<td>33<\/td>\n<td>45<\/td>\n<td>60<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<br \/>DIMENSION (SIZE 18~140)<\/p>\n<p>                <\/p>\n<p>\n<p>\n<p>\n<img decoding=\"async\" src=\"https:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-4.jpg\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Product Description Model:Rexroth piston pump &amp; motorA10VSO Side Port Series 16\/18\/28\/45\/71\/100\/140Operating pressure range &#8211; inlet:Absolute pressure at port SPalx min &#8212;&#8212;&#8212;-0.8 barPalx max &#8212;&#8212;&#8212;-30 bar Operating pressure range &#8211; outlet:Pressing at port BNominal pressure Pn&#8212;&#8212;&#8212;-280 barPeak pressure Pmax&#8212;&#8212;&#8212;-350 barApplication with intermittent operating pressures up to 315 bar at 10% duty are permissible. Features:1 for open-loop [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[5],"tags":[49,414,385,386,415,416,417,1037,751,1038,418,419,420],"class_list":["post-1618","post","type-post","status-publish","format-standard","hentry","category-product-catalog","tag-hydraulic","tag-hydraulic-piston-pump","tag-hydraulic-pump","tag-hydraulic-pump-pump","tag-hydraulic-pump-rexroth","tag-hydraulic-rexroth","tag-piston-hydraulic","tag-piston-hydraulic-pump","tag-price-hydraulic","tag-pump-hydraulic-piston","tag-rexroth-hydraulic","tag-rexroth-hydraulic-piston-pump","tag-rexroth-hydraulic-pump"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/posts\/1618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/comments?post=1618"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/posts\/1618\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/media?parent=1618"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/categories?post=1618"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/ko\/wp-json\/wp\/v2\/tags?post=1618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}