Opis produktu
Suncenter Double Acting Air CZPT n Piston Gas Booster Pump
Compressed Air CZPT n Gas Booster Pump- DGA/DGD/DGT Series
Suncenter Air CZPT n Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.
Główne cechy obejmują:
- Compressed Air driven – no electricity required (connect to normal CZPT )
- Aby wydłużyć żywotność pompy, ciśnienie powietrza napędowego powinno
not be higher than 8 bar
- Nie jest wymagany smar do linii lotniczych
- Hydrocarbon free – separation between air and gas sections
- Pressures to 80Mpa (11,600 psi)
- Szeroka gama modeli o różnych przełożeniach
- Wbudowane chłodzenie w większości modeli
- Easy to install, operate and maintain
- Best price / performance ratio
- Brak ryzyka narażenia na ciepło, płomienie lub iskry, zabezpieczenie przed wybuchem
- Automatic pressure holding, whatever the cause of the pressure drop, the CZPT center pump will automatically start, keep the loop pressure constant
- Applicable gas: Argon/Helium/Hydrogen/Oxygen/NO2/CH4/LNG/LPG/CNG/FM200 etc.
AplikacjaS
- Pressure test with gas
- Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
- Charging of gas cylinder and accumulator with nitrogen
- Supply for isolating gas systems
- Gas assisted injection molding
- Transfer of oxygen cylinders
- Charging of breathing air bottles
- Leak test
- Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
- Safety valve adjusting
DGA series gas booster pumps(Single acting, single air drive head):
DGA pumps are CZPT with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.
| Model | Pressure boost ratio | Min. gas Ciśnienie wlotowe PA (bar) |
Max.gas Ciśnienie wlotowe PA (bar) |
Max. gas outlet pressure PB (bar) |
Driven air pressure PL | Formula to calculate gas outlet pressure PB |
Połączenie: Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
| DGA02 | 2:1 | 1.0 | 16 | 16 | 2bar-8 bar | 2X PL | 1/2 / 1/2 | 960 (at PA of 6 bar ) |
| DGA05 | 5:1 | 0 | 40 | 40 | 2bar-8 bar | 5XPL | 1/2 / 1/2 | 680(at PA of 6 bar ) |
| DGA06 | 6:1 | 2.0 | 48 | 48 | 2bar-8 bar | 6XPL | 1/2 / 1/2 | 360(at PA of 10 bar ) |
| DGA10 | 10:1 | 3.5 | 80 | 80 | 2bar-8 bar | 10 PDL | 3/8/ 3/8 | 210(at PA of 10 bar ) |
| DGA25 | 25:1 | 7.0 | 200 | 200 | 2bar-8 bar | 25XPL | 1/4/ 1/4 | 120(at PA of 20 bar ) |
| DGA40 | 40:1 | 10 | 320 | 320 | 2bar-8 bar | 40PDL | 1/4/ 1/4 | 200(at PA of 40 bar ) |
| DGA60 | 60:1 | 20 | 480 | 480 | 2bar-8 bar | 60XPL | 1/4/ 1/4 | 180(at PA of 40 bar ) |
| DGA100 | 100:1 | 25 | 800 | 800 | 2bar-8 bar | 100 PDL | 1/4/ M14X1.5 | 136(at PA of 40 bar ) |
Technical spcification
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
DGD series gas booster pumps(Double acting ):
DGD series pumps are double acting, with single air driven heads type.
- DGD pumps are available with high quality seals, which provide significantly better service life
- Double pump heads with exhaust cooling devices.
- All components in contact with the gas are made of stainless steel.
- Pipes mounting way are CZPT as CZPT ized.
| Model | Pressure boost ratio | Min. gas Ciśnienie wlotowe PA (bar) |
Max.gas Ciśnienie wlotowe PA (bar) |
Max. gas outlet pressure PB (bar) |
Driven air pressure PL | Formula to calculate gas outlet pressure PB |
Połączenie: Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
| DGD10 | 10:1 | 3.5 | 80 | 80 | 2bar-8 bar | 10XPL+ PA | 3/8/3/8 | 410(at PA of 6 bar ) |
| DGD25 | 25:1 | 10 | 200 | 200 | 2bar-8 bar | 25XPL+ PA | 1/4/1/4 | 396(at PA of 20 bar ) |
| DGD40 | 40:1 | 15 | 320 | 320 | 2bar-8 bar | 40XPL+ PA | 1/4/1/4 | 320(at PA of 40 bar ) |
| DGD60 | 60:1 | 25 | 480 | 480 | 2bar-8 bar | 60XPL+ PA | 1/4/1/4 | 215(at PA of 40 bar ) |
| DGD100 | 100:1 | 35 | 800 | 800 | 2bar-8 bar | 100XPL+ PA | 1/4/M14*1.5 | 300(at PA of 60 bar ) |
| DGD130 | 130:1 | 50 | 1040 | 1040 | 2bar-8 bar | 130XPL+ PA | 1/4/M14*1.5 | 180(at PA of 60 bar ) |
Specyfikacja techniczna
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
2DGD series gas booster pumps(Double acting, double air driven heads ):
| Model | Pressure boost ratio | Min. gas Ciśnienie wlotowe PA (bar) |
Max.gas Ciśnienie wlotowe PA (bar) |
Max. gas outlet pressure PB (bar) |
Driven air pressure PL | Formula to calculate gas outlet pressure PB |
Połączenie: Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
| 2DGD10 | 10:1 | 3 | 80 | 80 | 2bar-8 bar | 2bar-8 bar | 1/2 / 1/2 | 980(at PA of 6 bar ) |
| 2DGD25 | 25:1 | 6 | 200 | 200 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 560(at PA of 10 bar ) |
| 2DGD40 | 40:1 | 25 | 320 | 320 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 480(at PA of 40 bar ) |
| 2DGD60 | 60:1 | 30 | 480 | 480 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 320(at PA of 40 bar ) |
Specyfikacja techniczna
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 ba
DGT series gas booster pumps(Double acting, double stage, single air drive head ):
DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.
- DGT pumps are available with high quality seals, which provide significantly better service life
- Double pump heads with exhaust cooling devices.
- All parts in contact with the gas are made of stainless steel.
| Model | Pressure boost ratio | Min. gas Ciśnienie wlotowe PA (bar) |
Max.gas Ciśnienie wlotowe PA (bar) |
Max. gas outlet pressure PB (bar) |
Driven air pressure PL | Formula to calculate gas outlet pressure PB |
Połączenie: Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
| DGT25 | 25:1 | 0.1 | 10 | 200 | 2-8 bar | 25XPL+3.5XPA | 3/8/ 1/4 | 136(at PA of 8 bar ) |
| DGT40 | 40:1 | 0.1 | 10 | 320 | 2-8 bar | 40PDL+ 6XPA | 3/8/ 1/4 | 124(at PA of 8 bar ) |
| DGT10/60 | 10:1/60:1 | 0.1 | 10 | 480 | 2-8 bar | 60XPL+6X PA | 3/8/ 1/4 | 84(at PA of 8 bar ) |
| DGT25/60 | 25:1/60:1 | 10 | 25 | 480 | 2-8 bar | 60XPL+2.5XPA | 3/8/ 1/4 | 80(at PA of 15 bar ) |
| DGT100 | 100:1 | 0.1 | 10 | 800 | 2-8 bar | 100 PDL+10XPA | 3/8/ M14*1.5 | 63(at PA of 8 bar ) |
Specyfikacja techniczna
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
SUNCENTER Air CZPT n Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.
Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.
As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.
SUNCENTER Air CZPT n Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; CZPT mobile regulator detecting and telecommunication cable inflatable appliances.
How to Select CZPT center Air CZPT n Gas Boosters/Systems?
In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:
1.What is your present gas pressure?( )bar
2.What is your gas?oxygen gas,nitrogen gas or other gases?
3.What outlet gas pressure do you want?( )bar
4.What driven air pressure (of your CZPT ) can you offer?( )bar,
because CZPT booster is completely air operated and no need any electricity
5.What outlet gas flow rate do you need?( )L/min
Centrum CZPT w HangZhou, CZPT Control Equipment Co., Ltd jest spółką członkowską centrum CZPT, zlokalizowanego w mieście HangZhou w prowincji ZheJiang, w regionie CZPT. Z ponad 15-letnim doświadczeniem w dziedzinie wymiany i sterowania ciśnieniem płynów, dostarczamy pneumatyczne i hydrauliczne pompy wspomagające, systemy i rozwiązania CZPT dla użytkowników CZPT na całym świecie. Dzięki najwyższej jakości produktów CZPT, konkurencyjnym cenom oraz doskonałej obsłudze posprzedażowej, zyskaliśmy znakomitą reputację w branży.
Nasze główne produkty to:
Pompy wspomagające wysokiego ciśnienia (pompa wspomagająca gaz CZPT n Air, pompa wspomagająca ciecz CZPT n Air, wzmacniacze powietrza)
Systemy wysokiego ciśnienia (stacje wspomagające gaz/ciecz, maszyna napełniająca FM200, rozprężarka rur CZPT)
Sprzęt do testów wysokociśnieniowych (maszyna do testów hydraulicznych/pęknięć/hydrostatycznych, maszyna do testów cylindrów,
Stanowisko probiercze zaworów, stanowisko do testowania impulsów CZPT itp.)
Zastosowanie produktu
Przemysł naftowy, przemysł gazowy, przemysł CZPT, walki CZPT, instytucje badawcze itp.
Nasza usługa
13 miesięcy bezpłatnej gwarancji od daty zakupu i bezpłatne wsparcie techniczne przez cały okres użytkowania
