{"id":1686,"date":"2022-03-25T21:37:30","date_gmt":"2022-03-25T21:37:30","guid":{"rendered":"https:\/\/pistonpumps.top\/suncenter-cheap-double-acting-air-driven-piston-gas-booster-pump-with-ce-certificate-top-quality-low-price\/"},"modified":"2022-03-25T21:37:30","modified_gmt":"2022-03-25T21:37:30","slug":"suncenter-cheap-double-acting-air-driven-piston-gas-booster-pump-with-ce-certificate-top-quality-low-price","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/pl\/suncenter-cheap-double-acting-air-driven-piston-gas-booster-pump-with-ce-certificate-top-quality-low-price\/","title":{"rendered":"Suncenter  Cheap Double Acting Air Driven Piston Gas Booster Pump with ce certificate top quality low price"},"content":{"rendered":"<p>\n<h2>Opis produktu<\/h2>\n<p>\n<p>                        <strong><u>Suncenter Double Acting Air CZPT n Piston Gas Booster Pump<\/u><\/strong><\/p>\n<p><strong>Compressed Air CZPT n Gas Booster Pump- DGA\/DGD\/DGT Series\u00a0<\/strong><\/p>\n<p>Suncenter Air CZPT n Gas Boosters provide for pressures up to\u00a080Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.\u00a0<\/p>\n<p>G\u0142\u00f3wne cechy obejmuj\u0105:\u00a0<\/p>\n<ol>\n<li>Compressed Air driven &#8211;\u00a0no electricity required (connect to normal CZPT )<\/li>\n<li>Aby wyd\u0142u\u017cy\u0107 \u017cywotno\u015b\u0107 pompy, ci\u015bnienie powietrza nap\u0119dowego powinno\u00a0<\/li>\n<\/ol>\n<p>not be higher than\u00a08 bar<\/p>\n<ol>\n<li>Nie jest wymagany smar do linii lotniczych\u00a0<\/li>\n<li>Hydrocarbon free &#8211;\u00a0separation between air and gas sections\u00a0<\/li>\n<li>Pressures to 80Mpa (11,600 psi)\u00a0\u00a0<\/li>\n<li>Szeroka gama modeli o r\u00f3\u017cnych prze\u0142o\u017ceniach<\/li>\n<li>Wbudowane ch\u0142odzenie w wi\u0119kszo\u015bci modeli\u00a0<\/li>\n<li>Easy\u00a0to\u00a0install, operate and maintain<\/li>\n<li>Best price \/\u00a0performance ratio\u00a0<\/li>\n<li>Brak ryzyka nara\u017cenia na ciep\u0142o, p\u0142omienie lub iskry, zabezpieczenie przed wybuchem\u00a0<\/li>\n<li>Automatic pressure holding,\u00a0whatever the cause of the pressure drop, the CZPT center\u00a0\u00a0\u00a0pump will automatically start, keep the loop pressure constant<\/li>\n<li>Applicable gas: Argon\/Helium\/Hydrogen\/Oxygen\/NO2\/CH4\/LNG\/LPG\/CNG\/FM200 etc.<\/li>\n<\/ol>\n<p><\/p>\n<p>\u00a0<strong>Aplikacja<\/strong><strong>S\u00a0<\/strong><\/p>\n<p>\u00a0<\/p>\n<ol>\n<li>Pressure test with gas<\/li>\n<li>Gas transfer and filling<\/li>\n<\/ol>\n<p>(Argon\/Helium\/Hydrogen\/Oxygen\/Nitrogen\/CO2\/NO2\/CH4\/LNG\/LPG\/CNG\/FM200 etc.)<\/p>\n<ol>\n<li>Charging of gas cylinder and accumulator with nitrogen<\/li>\n<li>Supply for isolating gas systems<\/li>\n<li>Gas assisted injection molding<\/li>\n<li>Transfer of oxygen cylinders<\/li>\n<li>Charging\u00a0of\u00a0breathing\u00a0air\u00a0bottles<\/li>\n<li>Leak\u00a0test\u00a0<\/li>\n<li>Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components<\/li>\n<li>Safety valve adjusting\u00a0<\/li>\n<\/ol>\n<p><strong>DGA series gas booster pumps(Single acting, single air drive head):<\/strong><strong>\u00a0<\/strong><br \/>DGA pumps are CZPT  with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.<\/p>\n<p>\u00a0<\/p>\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Pressure boost ratio<\/td>\n<td>Min. gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max.gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max. gas<br \/>outlet pressure P<sub>B<\/sub>\u00a0(bar)<\/td>\n<td>Driven air pressure\u00a0\u00a0P<sub>L<\/sub><\/td>\n<td>Formula to<br \/>calculate gas outlet pressure P<sub>B<\/sub><\/td>\n<td>Po\u0142\u0105czenie:<br \/>Gas Inlet \/<br \/>Gas outlet (NPT thread)<\/td>\n<td>Max. flow at driven air pressure of 6bar (L\/min)<\/td>\n<\/tr>\n<tr>\n<td>DGA02<\/td>\n<td>2:1<\/td>\n<td>1.0<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>2bar-8 bar<\/td>\n<td>2X P<sub>L<\/sub><\/td>\n<td>1\/2 \/\u00a01\/2<\/td>\n<td>960 (at P<sub>A\u00a0<\/sub>of 6\u00a0bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGA05<\/td>\n<td>5:1<\/td>\n<td>0<\/td>\n<td>40<\/td>\n<td>40\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>5XP<sub>L<\/sub><\/td>\n<td>1\/2 \/\u00a01\/2<\/td>\n<td>680(at P<sub>A\u00a0<\/sub>of 6\u00a0bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGA06<\/td>\n<td>6:1<\/td>\n<td>2.0<\/td>\n<td>48<\/td>\n<td>48<\/td>\n<td>2bar-8 bar<\/td>\n<td>6XP<sub>L<\/sub><\/td>\n<td>1\/2 \/\u00a01\/2<\/td>\n<td>360(at P<sub>A\u00a0<\/sub>of 10 bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGA10<\/td>\n<td>10:1<\/td>\n<td>3.5<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>2bar-8 bar<\/td>\n<td>10 PD<sub>L<\/sub><\/td>\n<td>3\/8\/ 3\/8<\/td>\n<td>210(at P<sub>A\u00a0<\/sub>of 10 bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGA25<\/td>\n<td>25:1<\/td>\n<td>7.0\u00a0<\/td>\n<td>200<\/td>\n<td>200\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>25XP<sub>L<\/sub><\/td>\n<td>1\/4\/ 1\/4<\/td>\n<td>120(at P<sub>A\u00a0<\/sub>of 20 bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGA40<\/td>\n<td>40:1<\/td>\n<td>10<\/td>\n<td>320<\/td>\n<td>320<\/td>\n<td>2bar-8 bar<\/td>\n<td>40PD<sub>L<\/sub><\/td>\n<td>1\/4\/ 1\/4<\/td>\n<td>200(at P<sub>A\u00a0<\/sub>of 40 bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGA60<\/td>\n<td>60:1<\/td>\n<td>20\u00a0<\/td>\n<td>480<\/td>\n<td>480\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>60XP<sub>L<\/sub><\/td>\n<td>1\/4\/ 1\/4<\/td>\n<td>180(at P<sub>A\u00a0<\/sub>of 40 bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGA100<\/td>\n<td>100:1<\/td>\n<td>25<\/td>\n<td>800<\/td>\n<td>800<\/td>\n<td>2bar-8 bar<\/td>\n<td>100 PD<sub>L<\/sub><\/td>\n<td>1\/4\/ M14X1.5<\/td>\n<td>136(at P<sub>A\u00a0<\/sub>of 40 bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Technical spcification<\/strong><br \/>Note:\u00a0\u00a0P<sub>L<\/sub>: driven air pressure\u00a0\u00a0\u00a0P<sub>A<\/sub>: gas inlet pressure\u00a0\u00a0\u00a0P<sub>B<\/sub>: gas outlet pressure\u00a0\u00a0<br \/>In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8\u00a0bar<br \/><strong>DGD series gas booster pumps(Double acting ):<\/strong><br \/>DGD series pumps are double acting, with single air driven heads type.\u00a0<strong>\u00a0<\/strong>\u00a0<\/p>\n<ol>\n<li>DGD\u00a0pumps\u00a0are\u00a0available\u00a0with high quality seals, which\u00a0provide\u00a0significantly\u00a0better\u00a0service\u00a0life<\/li>\n<li>Double pump heads with exhaust cooling devices.\u00a0<\/li>\n<li>All components in contact with the gas are made of stainless steel.\u00a0<\/li>\n<li>Pipes mounting way are CZPT  as CZPT ized.\u00a0<\/li>\n<\/ol>\n<p>\u00a0<\/p>\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Pressure boost ratio<\/td>\n<td>Min. gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max.gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max. gas<br \/>outlet pressure P<sub>B<\/sub>\u00a0(bar)<\/td>\n<td>Driven air pressure\u00a0\u00a0P<sub>L<\/sub><\/td>\n<td>Formula to<br \/>calculate gas outlet pressure P<sub>B<\/sub><\/td>\n<td>Po\u0142\u0105czenie:<br \/>Gas Inlet \/<br \/>Gas outlet (NPT thread)<\/td>\n<td>Max. flow at driven air pressure of 6bar (L\/min)<\/td>\n<\/tr>\n<tr>\n<td>DGD10<\/td>\n<td>10:1<\/td>\n<td>3.5<\/td>\n<td>80<\/td>\n<td>80\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>10XPL+ PA<\/td>\n<td>3\/8\/3\/8<\/td>\n<td>410(at PA of 6\u00a0bar )<\/td>\n<\/tr>\n<tr>\n<td>DGD25<\/td>\n<td>25:1<\/td>\n<td>10\u00a0<\/td>\n<td>200<\/td>\n<td>200\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>25XPL+ PA<\/td>\n<td>1\/4\/1\/4<\/td>\n<td>396(at PA of 20 bar )<\/td>\n<\/tr>\n<tr>\n<td>DGD40<\/td>\n<td>40:1<\/td>\n<td>15\u00a0<\/td>\n<td>320<\/td>\n<td>320\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>40XPL+ PA<\/td>\n<td>1\/4\/1\/4<\/td>\n<td>320(at PA of 40 bar )<\/td>\n<\/tr>\n<tr>\n<td>DGD60<\/td>\n<td>60:1<\/td>\n<td>25\u00a0<\/td>\n<td>480<\/td>\n<td>480\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>60XPL+ PA<\/td>\n<td>1\/4\/1\/4<\/td>\n<td>215(at PA of 40 bar )<\/td>\n<\/tr>\n<tr>\n<td>DGD100<\/td>\n<td>100:1<\/td>\n<td>35\u00a0<\/td>\n<td>800<\/td>\n<td>800\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>100XPL+ PA<\/td>\n<td>1\/4\/M14*1.5<\/td>\n<td>300(at PA of 60 bar )<\/td>\n<\/tr>\n<tr>\n<td>DGD130<\/td>\n<td>130:1<\/td>\n<td>50\u00a0<\/td>\n<td>1040<\/td>\n<td>1040\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>130XPL+ PA<\/td>\n<td>1\/4\/M14*1.5<\/td>\n<td>180(at PA of 60 bar )<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<strong>Specyfikacja techniczna<\/strong><br \/>Note:\u00a0\u00a0P<sub>L<\/sub>: driven air pressure\u00a0\u00a0\u00a0P<sub>A<\/sub>: gas inlet pressure\u00a0\u00a0\u00a0P<sub>B<\/sub>: gas outlet pressure\u00a0\u00a0<br \/>In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8\u00a0bar<\/p>\n<p><strong>2DGD series gas booster pumps(Double acting, double air driven heads ):<\/strong><\/p>\n<p>\u00a0<\/p>\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Pressure boost ratio<\/td>\n<td>Min. gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max.gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max. gas<br \/>outlet pressure P<sub>B<\/sub>\u00a0(bar)<\/td>\n<td>Driven air pressure\u00a0\u00a0P<sub>L<\/sub><\/td>\n<td>Formula to<br \/>calculate gas outlet pressure P<sub>B<\/sub><\/td>\n<td>Po\u0142\u0105czenie:<br \/>Gas Inlet \/<br \/>Gas outlet (NPT thread)<\/td>\n<td>Max. flow at driven air pressure of 6bar (L\/min)<\/td>\n<\/tr>\n<tr>\n<td>2DGD10<\/td>\n<td>10:1<\/td>\n<td>3<\/td>\n<td>80<\/td>\n<td>80\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>2bar-8 bar<\/td>\n<td>1\/2 \/\u00a01\/2<\/td>\n<td>980(at PA of 6\u00a0bar )<\/td>\n<\/tr>\n<tr>\n<td>2DGD25<\/td>\n<td>25:1<\/td>\n<td>6<\/td>\n<td>200<\/td>\n<td>200\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>2bar-8 bar<\/td>\n<td>3\/8 \/\u00a03\/8<\/td>\n<td>560(at PA of 10 bar )<\/td>\n<\/tr>\n<tr>\n<td>2DGD40<\/td>\n<td>40:1<\/td>\n<td>25<\/td>\n<td>320<\/td>\n<td>320\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>2bar-8 bar<\/td>\n<td>3\/8 \/\u00a03\/8<\/td>\n<td>480(at PA of 40 bar )<\/td>\n<\/tr>\n<tr>\n<td>2DGD60<\/td>\n<td>60:1<\/td>\n<td>30<\/td>\n<td>480<\/td>\n<td>480\u00a0<\/td>\n<td>2bar-8 bar<\/td>\n<td>2bar-8 bar<\/td>\n<td>3\/8 \/\u00a03\/8<\/td>\n<td>320(at PA of 40 bar )<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<strong>Specyfikacja techniczna<\/strong><br \/>Note:\u00a0\u00a0P<sub>L<\/sub>: driven air pressure\u00a0\u00a0\u00a0P<sub>A<\/sub>: gas inlet pressure\u00a0\u00a0\u00a0P<sub>B<\/sub>: gas outlet pressure\u00a0\u00a0<br \/>In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8\u00a0ba<\/p>\n<p><strong>DGT series gas booster pumps(Double acting, double stage, single air drive head ):<\/strong><br \/>DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.\u00a0<\/p>\n<ol>\n<li>DGT\u00a0pumps\u00a0are\u00a0available\u00a0with high quality seals, which\u00a0provide\u00a0significantly\u00a0better\u00a0service\u00a0life\u00a0<\/li>\n<li>Double pump heads with exhaust cooling devices.\u00a0<\/li>\n<li>All\u00a0parts\u00a0in\u00a0contact\u00a0with\u00a0the\u00a0gas\u00a0are\u00a0made\u00a0of\u00a0stainless\u00a0steel.\u00a0\u00a0\u00a0\u00a0<\/li>\n<\/ol>\n<p>\u00a0<\/p>\n<p>\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Pressure boost ratio<\/td>\n<td>Min. gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max.gas<br \/>Ci\u015bnienie wlotowe<br \/>P<sub>A<\/sub>\u00a0(bar)<\/td>\n<td>Max. gas<br \/>outlet pressure P<sub>B<\/sub>\u00a0(bar)<\/td>\n<td>Driven air pressure\u00a0\u00a0P<sub>L<\/sub><\/td>\n<td>Formula to<br \/>calculate gas outlet pressure P<sub>B<\/sub><\/td>\n<td>Po\u0142\u0105czenie:<br \/>Gas Inlet \/<br \/>Gas outlet (NPT thread)<\/td>\n<td>Max. flow at driven air pressure of 6bar (L\/min)<\/td>\n<\/tr>\n<tr>\n<td>DGT25<\/td>\n<td>25:1<\/td>\n<td>0.1<\/td>\n<td>10<\/td>\n<td>200<\/td>\n<td>2-8 bar<\/td>\n<td>25XP<sub>L<\/sub>+3.5XP<sub>A<\/sub><\/td>\n<td>3\/8\/ 1\/4<\/td>\n<td>136(at P<sub>A<\/sub>\u00a0of 8\u00a0bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGT40<\/td>\n<td>40:1<\/td>\n<td>0.1<\/td>\n<td>10<\/td>\n<td>320<\/td>\n<td>2-8 bar<\/td>\n<td>40PD<sub>L<\/sub>+ 6XP<sub>A<\/sub><\/td>\n<td>3\/8\/ 1\/4<\/td>\n<td>124(at P<sub>A<\/sub>\u00a0of 8\u00a0bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGT10\/60<\/td>\n<td>10:1\/60:1<\/td>\n<td>0.1<\/td>\n<td>10<\/td>\n<td>480<\/td>\n<td>2-8 bar<\/td>\n<td>60XP<sub>L<\/sub>+6X P<sub>A<\/sub><\/td>\n<td>3\/8\/ 1\/4<\/td>\n<td>84(at P<sub>A<\/sub>\u00a0of 8\u00a0bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGT25\/60<\/td>\n<td>25:1\/60:1<\/td>\n<td>10<\/td>\n<td>25<\/td>\n<td>480<\/td>\n<td>2-8 bar<\/td>\n<td>60XP<sub>L<\/sub>+2.5XP<sub>A<\/sub><\/td>\n<td>3\/8\/ 1\/4<\/td>\n<td>80(at P<sub>A<\/sub>\u00a0of 15 bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>DGT100<\/td>\n<td>100:1<\/td>\n<td>0.1<\/td>\n<td>10<\/td>\n<td>800<\/td>\n<td>2-8 bar<\/td>\n<td>100 PD<sub>L<\/sub>+10XP<sub>A<\/sub><\/td>\n<td>3\/8\/ M14*1.5<\/td>\n<td>63(at P<sub>A<\/sub>\u00a0of 8\u00a0bar<sub>\u00a0<\/sub>)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Specyfikacja techniczna<\/strong><br \/>Note:\u00a0\u00a0P<sub>L<\/sub>: driven air pressure\u00a0\u00a0\u00a0P<sub>A<\/sub>: gas inlet pressure\u00a0\u00a0\u00a0P<sub>B<\/sub>: gas outlet pressure\u00a0\u00a0<br \/>In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8\u00a0bar<\/p>\n<p>SUNCENTER Air CZPT n Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.<\/p>\n<p>Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.<\/p>\n<p>As a\u00a0result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a\u00a0combination of these models can be used to achieve different operating pressures and flow capacities.\u00a0<\/p>\n<p>SUNCENTER\u00a0Air CZPT n Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; CZPT mobile regulator detecting and telecommunication cable inflatable appliances.\u00a0\u00a0 \u00a0 \u00a0\u00a0<\/p>\n<p><strong>How to Select CZPT center Air CZPT n Gas Boosters\/Systems?<\/strong><\/p>\n<p><strong>In order to choose suitable booster pump or systems for you,<\/strong><br \/><strong>please kindly reply us the following questions:<\/strong><\/p>\n<p><strong>1.What is your present gas pressure?(\u00a0\u00a0\u00a0\u00a0)bar<\/strong><\/p>\n<p><strong>2.What is your gas?oxygen gas,nitrogen gas or other gases?<\/strong><\/p>\n<p><strong>3.What outlet gas pressure do you want?(\u00a0\u00a0\u00a0\u00a0)bar<\/strong><\/p>\n<p><strong>4.What driven air pressure (of your CZPT ) can you offer?(\u00a0\u00a0\u00a0\u00a0)bar,<\/strong><br \/><strong>because CZPT  booster is completely air operated and no need any electricity<\/strong><\/p>\n<p><strong>5.What outlet gas flow rate do you need?(\u00a0\u00a0\u00a0\u00a0)L\/min<\/strong><\/p>\n<p>Centrum CZPT w HangZhou, CZPT Control Equipment Co., Ltd jest sp\u00f3\u0142k\u0105 cz\u0142onkowsk\u0105 centrum CZPT, zlokalizowanego w mie\u015bcie HangZhou w prowincji ZheJiang, w regionie CZPT. Z ponad 15-letnim do\u015bwiadczeniem w dziedzinie wymiany i sterowania ci\u015bnieniem p\u0142yn\u00f3w, dostarczamy pneumatyczne i hydrauliczne pompy wspomagaj\u0105ce, systemy i rozwi\u0105zania CZPT dla u\u017cytkownik\u00f3w CZPT na ca\u0142ym \u015bwiecie. Dzi\u0119ki najwy\u017cszej jako\u015bci produkt\u00f3w CZPT, konkurencyjnym cenom oraz doskona\u0142ej obs\u0142udze posprzeda\u017cowej, zyskali\u015bmy znakomit\u0105 reputacj\u0119 w bran\u017cy.<br \/>\u00a0<br \/><strong>Nasze g\u0142\u00f3wne produkty to:<\/strong><br \/>Pompy wspomagaj\u0105ce wysokiego ci\u015bnienia (pompa wspomagaj\u0105ca gaz CZPT n Air, pompa wspomagaj\u0105ca ciecz CZPT n Air, wzmacniacze powietrza)<br \/>Systemy wysokiego ci\u015bnienia (stacje wspomagaj\u0105ce gaz\/ciecz, maszyna nape\u0142niaj\u0105ca FM200, rozpr\u0119\u017carka rur CZPT)<br \/>Sprz\u0119t do test\u00f3w wysokoci\u015bnieniowych (maszyna do test\u00f3w hydraulicznych\/p\u0119kni\u0119\u0107\/hydrostatycznych, maszyna do test\u00f3w cylindr\u00f3w,<br \/>Stanowisko probiercze zawor\u00f3w, stanowisko do testowania impuls\u00f3w CZPT itp.)<br \/>\u00a0<br \/><strong>Zastosowanie produktu<\/strong><br \/>Przemys\u0142 naftowy, przemys\u0142 gazowy, przemys\u0142 CZPT, walki CZPT, instytucje badawcze itp.<br \/>\u00a0<br \/><strong>Nasza us\u0142uga<\/strong><br \/>13 miesi\u0119cy bezp\u0142atnej gwarancji od daty zakupu i bezp\u0142atne wsparcie techniczne przez ca\u0142y okres u\u017cytkowania<\/p>\n<p>\u00a0                <\/p>\n<p>\n<p>\n<p>\n<img decoding=\"async\" src=\"https:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-4.jpg\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Product Description Suncenter Double Acting Air CZPT n Piston Gas Booster Pump Compressed Air CZPT n Gas Booster Pump- DGA\/DGD\/DGT Series\u00a0 Suncenter Air CZPT n Gas Boosters provide for pressures up to\u00a080Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[5],"tags":[],"class_list":["post-1686","post","type-post","status-publish","format-standard","hentry","category-product-catalog"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/posts\/1686","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/comments?post=1686"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/posts\/1686\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/media?parent=1686"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/categories?post=1686"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/tags?post=1686"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}