{"id":466,"date":"2020-10-11T07:09:02","date_gmt":"2020-10-11T07:09:02","guid":{"rendered":"https:\/\/pistonpumps.top\/air-conditioner-tool-two-stage-vacuum-pump\/"},"modified":"2020-10-11T07:09:02","modified_gmt":"2020-10-11T07:09:02","slug":"air-conditioner-tool-two-stage-vacuum-pump","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/pl\/air-conditioner-tool-two-stage-vacuum-pump\/","title":{"rendered":"Dwustopniowa pompa pr\u00f3\u017cniowa do klimatyzator\u00f3w"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Dwustopniowa pompa pr\u00f3\u017cniowa do klimatyzator\u00f3w\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Air Conditioner Tool Two Stage Vacuum Pump\" \/><\/p>\n<p><p>                                    urz\u0105dzenie klimatyzacyjne pompa pr\u00f3\u017cniowa dwufazowa<\/p>\n<p>Wst\u0119p<br \/>jeden&amp;kropka U\u017cywa&amp;dwukropek Stosowany jako narz\u0119dzie do naprawy ch\u0142odnictwa&amp;przecinek pasuje do klimatyzator\u00f3w i samochod\u00f3w oraz innego sprz\u0119tu&amp;p\u00f3\u0142<br \/>2&amp;okres Charakterystyka&amp;dwukropek Du\u017cy strumie\u0144 powietrza&amp;przecinek pozwala na znacznie dok\u0142adniejszy przep\u0142yw&amp;okres Pr\u0119dko\u015b\u0107 przep\u0142ywu mo\u017ce osi\u0105gn\u0105\u0107 4&amp;okres5CFM~5CFM&amp;okres 2800&amp;obr.\/min<br \/>cztery&amp;okres czasu Zawarto\u015b\u0107 obudowy&amp;dwukropek Odlew aluminiowy&amp;przecinek nie \u017celiwo surowe<br \/>5&amp;period Kolor pompy&amp;colon Ekologiczny&amp;przecinek Niebieski&amp;przecinek R\u00f3\u017cowy&amp;przecinek Czarny&amp;przecinek OEM jest r\u00f3wnie\u017c oferowany&amp;p\u00f3\u0142produkt<br \/>6&amp;okres Nasza energia&amp;okr\u0119g Posiadamy w\u0142asn\u0105 jednostk\u0119 produkcyjn\u0105&amp;przecinek, dzi\u0119ki czemu mo\u017cemy oferowa\u0107 produkty najwy\u017cszej jako\u015bci w realistycznych cenach&amp;okres Pi\u0119kny wygl\u0105d i praktyczno\u015b\u0107&amp;okres<br \/>Opakowanie i dwukropek w kartonie<br \/>Je\u015bli potrzebujesz wi\u0119cej szczeg\u00f3\u0142\u00f3w, skontaktuj si\u0119 ze mn\u0105 w dowolnym momencie.<br \/>Avy<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\">Model<br \/>\u00a0<\/td>\n<td>TM-&amp;period5A<br \/>\u00a0<\/td>\n<td>TM-1A<br \/>\u00a0<\/td>\n<td>TM-1&amp;okres 5A<br \/>\u00a0<\/td>\n<td>TM-2A<br \/>\u00a0<\/td>\n<td>TM-3A<br \/>\u00a0<\/td>\n<td>TM-4A<br \/>\u00a0<\/td>\n<td>TM-5A<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Przep\u0142yw &amp;lparcfm&amp;rpar<br \/>\u00a0<\/td>\n<td colspan=\"2\">220 V~&amp;sol50 Hz<br \/>\u00a0<\/td>\n<td>1CFM<br \/>30 l i solmin<br \/>\u00a0<\/td>\n<td>2 stopy sze\u015bcienne na minut\u0119<br \/>60L&amp;solmin<br \/>\u00a0<\/td>\n<td>3 stopy sze\u015bcienne na minut\u0119<br \/>90L&amp;solmin<br \/>\u00a0<\/td>\n<td>4 stopy sze\u015bcienne na minut\u0119<br \/>120 l i solmin<br \/>\u00a0<\/td>\n<td>6 st\u00f3p sze\u015bciennych na minut\u0119<br \/>180L&amp;solmin<br \/>\u00a0<\/td>\n<td>8 st\u00f3p sze\u015bciennych na minut\u0119<br \/>212L&amp;solmin<br \/>\u00a0<\/td>\n<td>9 st\u00f3p sze\u015bciennych na minut\u0119<br \/>260 l i solmin<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">110 V~&amp;sol60 Hz<br \/>\u00a0<\/td>\n<td>jeden&amp;okres2CFM<br \/>36 l i solmin<br \/>\u00a0<\/td>\n<td>dwa&amp;okres5CFM<br \/>72L&amp;solmin<br \/>\u00a0<\/td>\n<td>trzy i p\u00f3\u0142 stopy sze\u015bciennej (CFM)<br \/>108 l i solmin<br \/>\u00a0<\/td>\n<td>cztery i p\u00f3\u0142okresy 8CFM<br \/>144L&amp;solmin<br \/>\u00a0<\/td>\n<td>siedem i okres 2CFM<br \/>216L&amp;solmin<br \/>\u00a0<\/td>\n<td>9&amp;period6CFM<br \/>255 l i solmin<br \/>\u00a0<\/td>\n<td>11 st\u00f3p sze\u015bciennych na minut\u0119<br \/>312L&amp;solmin<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Prawdziwa najwy\u017csza pr\u00f3\u017cnia<br \/>\u00a0<\/td>\n<td>10Pa<br \/>75CZPT<br \/>\u00a0<\/td>\n<td>10Pa<br \/>75CZPT<br \/>\u00a0<\/td>\n<td>10Pa<br \/>75CZPT<br \/>\u00a0<\/td>\n<td>10Pa<br \/>75CZPT<br \/>\u00a0<\/td>\n<td>10Pa<br \/>75CZPT<br \/>\u00a0<\/td>\n<td>10Pa<br \/>75CZPT<br \/>\u00a0<\/td>\n<td>pi\u0119\u0107 Pa<br \/>35CZPT<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Moc&amp;lparHP&amp;rpar<br \/>\u00a0<\/td>\n<td>1&amp;sol6<br \/>\u00a0<\/td>\n<td>jeden&amp;sol4<br \/>\u00a0<\/td>\n<td>1&amp;sol4<br \/>\u00a0<\/td>\n<td>jeden&amp;sol3<br \/>\u00a0<\/td>\n<td>1&amp;sol2<br \/>\u00a0<\/td>\n<td>jeden&amp;sol2<br \/>\u00a0<\/td>\n<td>trzy&amp;sol4<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Pr\u0119dko\u015b\u0107 silnika &amp;lparr&amp;solmi&amp;rpar<br \/>\u00a0<\/td>\n<td>220 V~&amp;sol50 Hz<br \/>\u00a0<\/td>\n<td>1440<br \/>\u00a0<\/td>\n<td>1440<br \/>\u00a0<\/td>\n<td>1440<br \/>\u00a0<\/td>\n<td>1440<br \/>\u00a0<\/td>\n<td>1440<br \/>\u00a0<\/td>\n<td>1440<br \/>\u00a0<\/td>\n<td>1440<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>110 V~&amp;sol60 Hz<br \/>\u00a0<\/td>\n<td>1720<br \/>\u00a0<\/td>\n<td>1720<br \/>\u00a0<\/td>\n<td>1720<br \/>\u00a0<\/td>\n<td>1720<br \/>\u00a0<\/td>\n<td>1720<br \/>\u00a0<\/td>\n<td>1720<br \/>\u00a0<\/td>\n<td>1720<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Otw\u00f3r wlotowy &amp;lparopcjonalny&amp;rpar<br \/>\u00a0<\/td>\n<td>one&amp;sol4 SAE<br \/>\u00a0<\/td>\n<td>1&amp;sol4 SAE<br \/>\u00a0<\/td>\n<td>1&amp;sol4 SAE<br \/>\u00a0<\/td>\n<td>1&amp;sol4 SAE<br \/>\u00a0<\/td>\n<td>one&amp;sol4 SAE<br \/>\u00a0<\/td>\n<td>1&amp;sol4 SAE<br \/>\u00a0<\/td>\n<td>1&amp;sol4 SAE<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Potencja\u0142 naftowy &amp;lparml&amp;rpar<br \/>\u00a0<\/td>\n<td>sto sze\u015b\u0107dziesi\u0105t<br \/>\u00a0<\/td>\n<td>250<br \/>\u00a0<\/td>\n<td>dwie\u015bcie<br \/>\u00a0<\/td>\n<td>250<br \/>\u00a0<\/td>\n<td>320<br \/>\u00a0<\/td>\n<td>siedemset<br \/>\u00a0<\/td>\n<td>siedemset<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Proporcje &amp;lparmm&amp;rpar<br \/>\u00a0<\/td>\n<td>240&amp;115&amp;230<br \/>\u00a0<\/td>\n<td>249&amp;ast121&amp;ast230<br \/>\u00a0<\/td>\n<td>315&amp;ast125&amp;ast240<br \/>\u00a0<\/td>\n<td>340&amp;ast135&amp;ast260<br \/>\u00a0<\/td>\n<td>315&amp;ast135&amp;ast260<br \/>\u00a0<\/td>\n<td>390&amp;ast145&amp;ast280<br \/>\u00a0<\/td>\n<td>420&amp;ast155&amp;ast280<br \/>\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Fat&amp;lparkg&amp;rpar<br \/>\u00a0<\/td>\n<td>sze\u015b\u0107<br \/>\u00a0<\/td>\n<td>7&amp;okres 2<br \/>\u00a0<\/td>\n<td>7&amp;okresu 5<br \/>\u00a0<\/td>\n<td>8 i okres 8<br \/>\u00a0<\/td>\n<td>dziewi\u0119\u0107 i okres8<br \/>\u00a0<\/td>\n<td>15 i okres 5<br \/>\u00a0<\/td>\n<td>16<br \/>\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n<p><p><img decoding=\"async\" style=\"height:auto\" title=\"Dwustopniowa pompa pr\u00f3\u017cniowa do klimatyzator\u00f3w\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"Air Conditioner Tool Two Stage Vacuum Pump\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>air conditioner device two phase vacuum pump Introductionone&amp;period Utilizes&amp;colon Employed as a refrigeration fixing instrument&amp;comma fit for air conditioner and Auto and other equipments&amp;semi2&amp;time period Chacteristic&amp;colon Substantial stream charge&amp;comma the air can movement out far more entirely&amp;period The circulation fee could get to to 4&amp;period5CFM~5CFM&amp;time period 2800&amp;solrpmfour&amp;period of time The content of housing&amp;colon Die cast [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[857,392,393,401,239,240,892,402,242,893],"class_list":["post-466","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-air-conditioner-vacuum-pump","tag-air-pump-vacuum","tag-air-vacuum-pump","tag-pump-air-vacuum","tag-pump-vacuum","tag-pump-vacuum-pump","tag-two-stage-vacuum-pump","tag-vacuum-air-pump","tag-vacuum-pump","tag-vacuum-pump-two-stage"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/posts\/466","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/comments?post=466"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/posts\/466\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/media?parent=466"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/categories?post=466"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/pl\/wp-json\/wp\/v2\/tags?post=466"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}