{"id":100,"date":"2020-10-08T03:37:33","date_gmt":"2020-10-08T03:37:33","guid":{"rendered":"https:\/\/pistonpumps.top\/sf6-insulation-equipment-gas-recycling-device-sf6-gas-recovery-machine\/"},"modified":"2020-10-08T03:37:33","modified_gmt":"2020-10-08T03:37:33","slug":"sf6-insulation-equipment-gas-recycling-device-sf6-gas-recovery-machine","status":"publish","type":"post","link":"https:\/\/pistonpumps.top\/vi\/sf6-insulation-equipment-gas-recycling-device-sf6-gas-recovery-machine\/","title":{"rendered":"Thi\u1ebft b\u1ecb c\u00e1ch \u0111i\u1ec7n SF6, thi\u1ebft b\u1ecb t\u00e1i ch\u1ebf kh\u00ed SF6, m\u00e1y thu h\u1ed3i kh\u00ed SF6."},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Thi\u1ebft b\u1ecb c\u00e1ch \u0111i\u1ec7n SF6, thi\u1ebft b\u1ecb t\u00e1i ch\u1ebf kh\u00ed SF6, m\u00e1y thu h\u1ed3i kh\u00ed SF6.\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine\" \/><\/p>\n<p>\n<p><strong>Thi\u1ebft b\u1ecb t\u00e1i ch\u1ebf nhi\u00ean li\u1ec7u SF6 c\u00e1ch \u0111i\u1ec7n CZPT, thi\u1ebft b\u1ecb ph\u1ee5c h\u1ed3i nhi\u00ean li\u1ec7u SF6 CZPT GDQH-601-15<\/strong><\/p>\n<p><strong>I. D\u1eef li\u1ec7u CZPT<\/strong><\/p>\n<p>H\u1ec7 th\u1ed1ng ki\u1ec3m tra bao g\u1ed3m m\u00e1y n\u00e9n SF6, b\u01a1m ch\u00e2n kh\u00f4ng, h\u1ec7 th\u1ed1ng ng\u01b0ng t\u1ee5, b\u1ed3n ch\u1ee9a ch\u1ea5t l\u1ecfng, ch\u01b0\u01a1ng tr\u00ecnh l\u1ecdc t\u00edch h\u1ee3p v\u1edbi b\u1ed9 l\u1ecdc kh\u00f4 c\u00f3 th\u1ec3 t\u00e1i s\u1eed d\u1ee5ng, b\u1ed9 l\u1ecdc b\u1ee5i, van bi, \u0111\u1ed3ng h\u1ed3 \u0111o ch\u00e2n kh\u00f4ng, h\u1ec7 th\u1ed1ng \u0111i\u1ec7n, c\u1ea3m bi\u1ebfn \u00e1p su\u1ea5t, nhi\u1ec7t k\u1ebf, h\u1ec7 th\u1ed1ng c\u1ea3nh b\u00e1o v\u00e0 b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n.<\/p>\n<p>S\u1ea3n ph\u1ea9m n\u00e0y ph\u00f9 h\u1ee3p cho c\u00e1c thi\u1ebft b\u1ecb \u0111i\u1ec7n SF6, nh\u00e0 s\u1ea3n xu\u1ea5t GIS v\u00e0 c\u00e1c vi\u1ec7n nghi\u00ean c\u1ee9u.<\/p>\n<p>\u00a0<\/p>\n<p><strong>II. \u0110\u1eb7c \u0111i\u1ec3m<\/strong><\/p>\n<ul>\n<li>\u0110\u1ed1i v\u1edbi thi\u1ebft b\u1ecb l\u00e2n c\u1eadn, c\u00f4ng t\u1eafc SF6, h\u00fat ch\u00e2n kh\u00f4ng v\u00e0 \u0111o l\u01b0\u1eddng nhi\u00ean li\u1ec7u GIS.<\/li>\n<li>D\u00f9ng \u0111\u1ec3 h\u00fat ch\u00e2n kh\u00f4ng v\u00e0 \u0111o l\u01b0\u1eddng trong b\u1ec3 h\u00f3a l\u1ecfng.<\/li>\n<li>H\u00fat ch\u00e2n kh\u00f4ng cho h\u1ec7 th\u1ed1ng ho\u1ea1t \u0111\u1ed9ng \u0111\u1ed9c l\u1eadp v\u00e0 \u0111\u1ec3 \u0111o l\u01b0\u1eddng.<\/li>\n<li>\u0110\u00e3 n\u1ea1p l\u1ea1i kh\u00ed SF6 cho c\u00f4ng t\u1eafc.<\/li>\n<li>T\u00e1i ch\u1ebf kh\u00ed SF6 t\u1eeb thi\u1ebft b\u1ecb \u0111i\u1ec7n, bao g\u1ed3m x\u1eed l\u00fd n\u01b0\u1edbc v\u00e0 d\u1ea7u.<\/li>\n<li>Ph\u01b0\u01a1ng ph\u00e1p x\u1eed l\u00fd t\u00e1i ch\u1ebf, n\u1ea1p l\u1ea1i v\u00e0 tinh ch\u1ebf kh\u00ed SF6 kh\u00f4.<\/li>\n<li>T\u00e1i ch\u1ebf x\u0103ng SF6 t\u1eeb thi\u1ebft b\u1ecb SF6 v\u00e0 b\u1ec3 ch\u1ee9a ch\u1ea5t l\u1ecfng, \u0111o \u0111i\u1ec7n \u00e1p d\u01b0.<\/li>\n<li>N\u00e9n ch\u1ea5t l\u1ecfng \u0111\u1ec3 l\u01b0u tr\u1eef nh\u1eb1m t\u1ea1o ra x\u0103ng SF6.<\/li>\n<li>D\u1ec5 d\u00e0ng di chuy\u1ec3n.<\/li>\n<\/ul>\n<p>\u00a0<br \/>\u00a0<\/p>\n<p><strong>III. Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\">\n<p>Ph\u01b0\u01a1ng ph\u00e1p<\/p>\n<\/td>\n<td>\n<p>S\u1ef1 h\u00f3a l\u1ecfng \u0111\u00f3ng b\u0103ng, l\u00e0m m\u00e1t b\u1eb1ng kh\u00f4ng kh\u00ed, c\u00f3 th\u1ec3 di chuy\u1ec3n<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Nhi\u1ec7t \u0111\u1ed9 m\u00f4i tr\u01b0\u1eddng ho\u1ea1t \u0111\u1ed9ng<\/p>\n<\/td>\n<td>\n<p>-25\u00baC\u2014 +50\u00baC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>ch\u00e2n kh\u00f4ng t\u1ed1i cao\u00a0<\/p>\n<\/td>\n<td>\n<p>&lt;10Pa<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Ph\u00ed h\u00fat ch\u00e2n kh\u00f4ng<\/p>\n<\/td>\n<td>\n<p>16 m\u00b3\/h<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>T\u00e1i ch\u1ebf<\/p>\n<\/td>\n<td>\n<p>Bi\u1ebfn th\u1ec3 s\u01a1 b\u1ed9<\/p>\n<\/td>\n<td>\n<p>\u22641M Pa<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>L\u1ef1c CZPTinal<\/p>\n<\/td>\n<td>\n<p>&lt;0,05MPa<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>T\u1ef7 l\u1ec7<\/p>\n<\/td>\n<td>\n<p>n\u0103m,8 m\u00e9t<sup>3\/<\/sup>h<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>b\u01a1m h\u01a1i<\/p>\n<\/td>\n<td>\n<p>L\u1ef1c l\u01b0\u1ee3ng ban \u0111\u1ea7u<\/p>\n<\/td>\n<td>\n<p>&lt;133Pa CZPT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u00c1p su\u1ea5t CZPTinal<\/p>\n<\/td>\n<td>\n<p>\u22640,7 MPa\u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Gi\u00e1<\/p>\n<\/td>\n<td>\n<p>&gt;4m<sup>3<\/sup>\/h<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Gi\u00e1 r\u00f2 r\u1ec9 h\u00e0ng n\u0103m c\u1ee7a thi\u1ebft b\u1ecb<\/p>\n<\/td>\n<td>\n<p>&lt;1%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u1ee8ng su\u1ea5t thi\u1ebft k\u1ebf t\u1ed1i \u0111a<\/p>\n<\/td>\n<td>\n<p>4MPa<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>B\u1ec3 ch\u1ee9a<\/p>\n<\/td>\n<td>\n<p>15 l\u00edt<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Ph\u01b0\u01a1ng ph\u00e1p b\u1ea3o qu\u1ea3n<\/p>\n<\/td>\n<td>\n<p>X\u0103ng l\u1ecfng<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Ti\u1ebfng \u1ed3n\u00a0<\/p>\n<\/td>\n<td>\n<p>\u226475 dB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Ph\u01b0\u01a1ng ph\u00e1p t\u00e1i t\u1ea1o b\u1ed9 l\u1ecdc kh\u00f4<\/p>\n<\/td>\n<td>\n<p>ph\u01b0\u01a1ng ph\u00e1p x\u1eed l\u00fd k\u00edch ho\u1ea1t nhi\u1ec7t t\u00e1i t\u1ea1o ch\u00e2n kh\u00f4ng<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Cung c\u1ea5p \u0111i\u1ec7n<\/p>\n<\/td>\n<td>\n<p>\u0110i\u1ec7n \u00e1p xoay chi\u1ec1u 220V\/\u00b110%, 50HZ (t\u00f9y ch\u1ecdn 380V)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\u00a0T\u1ed5ng m\u1ee9c ti\u00eau th\u1ee5 \u0111i\u1ec7n n\u0103ng c\u1ee7a thi\u1ebft b\u1ecb<\/td>\n<td>\n<p>&lt;4KW<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>K\u00edch th\u01b0\u1edbc (mm)<\/p>\n<\/td>\n<td>\n<p>900mm*850mm*1650mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Tr\u1ecdng l\u01b0\u1ee3ng c\u01a1 th\u1ec3 (kg)<\/p>\n<\/td>\n<td>\n<p>185 ngh\u00ecn<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<p>\u00a0                            <\/p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"Thi\u1ebft b\u1ecb c\u00e1ch \u0111i\u1ec7n SF6, thi\u1ebft b\u1ecb t\u00e1i ch\u1ebf kh\u00ed SF6, m\u00e1y thu h\u1ed3i kh\u00ed SF6.\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/Vacuum-pump-5.jpg\" alt=\"SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>SF6 Insulation CZPT Fuel Recycling Device SF6 Fuel Restoration CZPT GDQH-601-fifteen I.\u00a0CZPT data The Check established contains SF6 compressor,\u00a0vacuum\u00a0pump,\u00a0condensation system,\u00a0liquid storage tank,\u00a0purification program constructed-in renewable dry filter,\u00a0dust filter,\u00a0ball valve,\u00a0vacuum\u00a0gauge,\u00a0electric technique,\u00a0pressure detection,\u00a0thermometer,\u00a0alarm management and instrument panel. It is suitable for SF6 electrical equipment,\u00a0GIS maker and institute. \u00a0 II.\u00a0Features For nearby gadget, SF6 switch, GIS fuel vacuuming [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[4,274,275],"class_list":["post-100","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-machine","tag-recovery-machine","tag-recycling-machine"],"_links":{"self":[{"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/posts\/100","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/comments?post=100"}],"version-history":[{"count":0,"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/posts\/100\/revisions"}],"wp:attachment":[{"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/media?parent=100"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/categories?post=100"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pistonpumps.top\/vi\/wp-json\/wp\/v2\/tags?post=100"}],"curies":[{"name":"trang web","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}