Xrf Analyzer for Precious Metals

Xrf Analyzer for Precious Metals

 Merchandise Description
It can qualitative and quantitation evaluation among different resources except component C, also, the apparatus can overall performance properly in Mg,Al,Si,S,P, and Mn which other equipment can not perform well. It primarily used in the adhering to fields, this kind of as steel,  fireproofing, non-ferrous industry, the high quality department, the plating thickness tests, ROSH inductor investigation and so forth.
 Principal Functions

(1).Correct: Examination benefits can be near to check damp chemical strategies.

(two).Quick pace: Screening large quantities elements in the sample only want few minutes.

(3).Non-reduction: It are unable to damage the actual physical and chemical properties in sample.

(4).Visually: Examination results are existing directly in graph.

(five).CZPT: It can not pollute the setting.
Principal technical parameter

Examination aspects Na-U,Mostly are Al,Si,P,S,K,Ca,Ti,V,Fe,Ni,Mn,Pb,Zn,Cu,Sn,Sb,As and so forth
investigation range one ppm-99.ninety nine%
measuring time All the contents evaluation only in one-two minutes
investigation precision Regular deviation ≤0.08%
examination mistake Up to the regular requirments
radiation dosage <25  μ sv/h
environment temperature fifteen ºC-35 ºC

 Principal allocation

(one). Detection system

 Detector

 Type: electric powered refrigeration SDD detector

 Be window thickness: 50um

 The greatest resolution: 130eV

 CZPT reaction range: 1keV-50keV

(2).X light tube (for X ray spectrometer)

 Voltage: ~ 50kV

 Maximum present: 1.0mA

 Maximum electricity: 50W

 Filament voltage: 2.0V

 Filament current: one.7A

 Ray out angle: 12 °

 Target: Mo

 Be window thickness: .5mm

(3).Substantial-voltage electricity source

 Input voltage: DC+24V ± 10%

 Input current: four.0A ( maximum )

 Output voltage: -5KV & 1mA

 Maximum electricity: 50W

 Voltage regulation rate: .01% ( from no load to entire load)

 Current adjustment price: .01% ( from no load to entire load)

 Ripple element: .1% ( P-P price)

 The security of eight hrs: .05%

(4). Vacuum pump

 Vacuum: vacuum take a look at 20Pa limit vacuum 2Pa

 (five). Optical integration design / system / vacuum cavity radiation protection

 X gentle tube, detector, the composite filtertreatment system, CCD, positioning program, automated collimator switching method processor optical path are built-in in a shut structure, ensure the security of optical program with a closed optical path method as a vacuum cavity, via the loop and the maze properly by making use of X ray greatest strength at the exact same time to make sure the ray zero overflow.
Packing & CZPT



 

Xrf Analyzer for Precious Metals