High CV Plunger Pump for Small Volume Regent Dispening

High CV Plunger Pump for Small Volume Regent Dispening

1. Generation Overview
The 50XX-P collection is a family of precision piston pumps which gives specific sampling and reagent dispensing. With substantial aspirating and drainage precision, this series pump is a higher functionality, dropped price and maintenance totally free precision piston pump and its existence time can be a lot more than five million cycles with out affecting the precision and accuracy. Piston pump has currently been extensively employed in medical and laboratory analytical instruments.
one.1. Traits Of 50XX-P Piston Pump
Номинално количество за дозиране: 100 ul ~ 5 ml, няколко вида за избор.
Inside of the existence cycle of pump, they have a high stability liquid quantitative precision. When tests medium is deionized h2o, the CV price as the following table: Proportion of liquid aspiration between overall ability CV (Coefficient of variation)
2%
<1.5%
>10%
<0.5%
A complete get rid of for cylinder:twelve.7mm
CZPT technological innovation to approach zirconia ceramics cylinder, rigorous inspection program, distinctive sealing solution, all these promise pump’s lifestyle time previously mentioned 5 million cycles without upkeep.
Wetted substance has a large chemical resistance.
one. A number of resources for choice, make sure chemical compatibility.
two. It has different sealing composition to match various operating problems.
Optical detection is at the finish place. Photoelectric sensor can guarantee regardless of whether pump is at the principal situation.
2.2. 50XX-P Series Specification
Max Dispense Quantity(Ul) a hundred 250 five hundred one thousand 2500 5000
Piston Diameter(Mm) 3.17 5.01 seven.08 10.01 15.eighty four 22.39
Volume per Stroke
(ul/phase)
.05 .125 .25 .5 1.25 two.five
Journey Length (mm) 12.seven
Lead (mm) 1.27
Distance per Stroke
(mm/action)
. 0571
Anticipated Existence (Cycles)one five million
Коефициент на вариация
(CV)2
1.five%
Dispense CZPT3 two%
Running Pressure(MPa) .3
Connection Port one/4-28 UNF, M6
Mediums4 drinking water, weak acid and bases etc.
Забележка:
1: Make sure you contact us if the medium is air.
2: The CV is tested under two% assortment.
three: Normal precision is analyzed underneath 2% selection.
four: It need to be confirmed if making use of other mediums.

 