Deep price Well Piston Pump No Clogging Submersible Sewage Centrifugal Pump with ce certificate top quality low price

Описание на продукта

Products Name:WQ sewage pump

Приложение:

WQ type sewage pumps widely used in agriculture, architecture,
mine, environment protection and industry, such as drainage slurry,
waste water, which contained short fibre, CZPT fibre, wastepaper,
sand and so on, it is also an ideal equipment for irrigation.

Operating conditions:

1,The maximum deep it is allowed in water is 5m from its center of impeller;
2,Max. medium temperature: +40
3,Trans medium’s PH:4-10;
4,Kinematics viscosity of the trans medium is:7*10-7-23*10-8m2/s;
5,Density of the trans medium limit;1.2*103kg/m3;*The solid diameter is about35mm.

Мотор:

1,Closed, externally ventilated
2,Insulation Class B
3,Protection IP68

Материал:

1,Pump body: Cast iron
2,Impeller: CZPT ior steel / Cast iron
3,Shaft with rotor: CZPT ior steel
4,Mechanical seal: CZPT steel/Carbon-ceramic
5,Thermal protector
6,Motor housing:Stainless steel
7,Single phase 220V-230V/50Hz
8,Three phase 380V/50Hz
9,Three phase 220V/440/60Hz if request

fault phenomenon failure cause elimination methods
  1.No CZPT supply or one or two phase CZPT supply is needed  
Check all phases of CZPT supply and restore CZPT supply
 
 
  2.Poor contact of ac contactor and burning of coil  
Repair or replace contactors
 
 
can not start 3.
The CZPT switch is not closed, malfunction or damaged
 
 
Close the switch and replace it if the CZPT indicator does not turn on
  4.
Thermal relay trip or damage
 
 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low  
Put water in the sink
 
 
  The motor burned  
Repair or replace the motor
 
 
  1.Line is loose  
Check wiring and tighten connectors
 
 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter CZPT supply for a few CZPT s, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump CZPT – suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage
 
The pump consumes too much CZPT
 
 
 
Too much flow, impeller wear
 
 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow

ЕТИКЕТИ: